Trouble-shooting

1. Power LED is not lit

l

 Check if the power cord is properly connected to the power outlet and the hub.

Make sure the power switch on the hub is turned ON.

2. LNK/Rx LED is not lit after connecting to an active workstation

l

 Check the power switch of the network devices attached to the hub; make sure

    they are turned ON.

l

 Check the network cable; make sure it is properly connected to the hub and the

    network device.

l

 Check the network cable; make sure the cable complies with EIA/TIA 568

    specification. Use straight-through minimum Category 3 grade cables.

l

 Do not use uplink port to connect to a workstation.

3. Uplink (16th) port’s LNK/Rx LED is not lit after uplink to another hub

l

 Check the network cable; make sure it is properly connected to both hubs.   One

    end of the cable should be connected to uplink port while the other end of the
    cable should be connected to a regular port.   Do not connect the cable to both
    uplink ports.

l

 Check the network cable; make sure the cable complies with EIA/TIA 568

    specification.

l

 Check the length of the network cable does not exceed 100 meters (300 feet).

l

 Make sure both hubs are powered ON.

4. AUI/BNC ports do not transmit

l

 Check the DIP switch setting.

l

 Check the AUI transceiver; make sure the SQE is set at OFF.

l

 Check the attachment of coaxial cable; make sure there’s no loose connection.

l

 Check the coaxial cable; make sure the segment is terminated with 50-ohm

    terminator.

9

Summary of Contents for ER-5398S

Page 1: ...DIMAX Ethernet Hub ER 5398S 18 Port Rackmount Ethernet Hub User s Manual S S L A N P R O F E I O N A L...

Page 2: ...tion If you suspect this equipment is causing interference turn your hub on and off while your radio or TV is showing interference to determine the source of the interference You can try to correct th...

Page 3: ...Chapter 1 Introduction 1 Chapter 2 Features Specifications 2 Chapter 3 Package Contents 3 Chapter 4 Physical Description 4 Chapter 5 Installation 6 Chapter 6 Trouble shooting 9 Contents...

Page 4: ...y as stand alone or distributed workgroup wiring center 1 Figure 1 2 Uplink to another hub Figure 1 1 ER 5398S Topology 1X 2X 3X 4X 5X 6X 7X 8X 13X 14X 15X 16MDI X 9X 10X 11X 12X 16MDI R O F E SS 18PO...

Page 5: ...rough cable n Complete sets of LEDs provide an easy diagnostic on the hub s and individual port s status n Standard 19 rackmount n Two year warranty 2 Specification n Standards IEEE 802 3 n 10Mbps Por...

Page 6: ...ors n Rackmount accessories n User s manual 3 Figure 3 1 Package contents 1X 2X 3X 4X 5X 6X 7X 8X 13X 14X 15X 16MDI X 9X 10X 11X 12X 16MDI L P R O F E S S 18 PORT 10 Mbps ER 5398 10BaseT Ethernet 1 3...

Page 7: ...DIMAX 1 2 3 4 ON BNC 1 BNC 2 AUI 1 AUI 2 Power 100 240VAC 1A L A N P R O F E S S I O N L 18 PORT 10 Mbps ER 5398 10BaseT Ethernet 1 3 5 7 9 Link Rx Partition Collision Jabber Power 2 4 6 8 10 12 14 16...

Page 8: ...Off Lit Off Flash Lit Off Power is supplied No power A valid link is established Data packets received No link is established This port is patitioned This port is working normally Collision detected...

Page 9: ...e network cable is connected on both ends and the attached network devices are powered on the green LNK Rx Link Status LED should be lit 3 Uplink to Another Hub with UTP cable Use uplink port to conne...

Page 10: ...ure 5 3 If the ER 5398S is at either end of the coaxial segment make sure terminate the open end of T connector with a 50 ohm terminator When using the AUI port firmly attach the AUI transceiver to th...

Page 11: ...the power socket on the rear panel of the unit Connect the power cord to the power outlet and turn on power switch The green Power LED on the front panel should be lit Figure 5 5 Connect the power 1 2...

Page 12: ...rkstation 3 Uplink 16th port s LNK Rx LED is not lit after uplink to another hub l Check the network cable make sure it is properly connected to both hubs One end of the cable should be connected to u...

Page 13: ...e network cables connect the cables back one by one to isolate the source of the collision l Check the network cable inferior cable quality will result in excessive collision and error packets 7 Jabbl...

Reviews: