EdilKamin MILLA H 12 Installation, Use And Maintenance Handbook Download Page 18

18

ENGLISH

THE FLUE:

Further to the general prescriptions, the flue must
•  only be used to discharge smoke
•  be correctly sized to satisfy the requirements of 

smoke discharge (EN 13384-1)

•  must preferably be insulated, in steel with a circular 

internal section. If rectangular, the corners must 
have a radius of not less than 20 mm, with a ratio 
of the internal dimensions of <1.5

•  must normally be at least 1.5 metres in vertical 

length

•  must have a constant cross section
•  must be waterproof and thermally insulated to 

ensure a good draw

•  must preferable have a collection chamber for 

non-combusted matter and condensation.

•  if pre-existing, it must be cleaned to prevent any 

fire hazard

•  in general, we recommend fitting a tube inside the 

existing masonry chimney if its diameter is greater 
than 150 mm. This recommendation is purely for 
guidance; the installer must assess wile installing, 
after the calculation of the draw.

INTUBATED SYSTEM:

Further to the general prescriptions, the intubated
system must:
• operate in negative pressure
• be open to inspection
• be compliant with local regulations.

THE CHIMNEY POT must:

• be wind-proof
• have an internal cross section equivalent to that of
the flue and a smoke outlet at least double that of
the interior of the flue
• extend beyond the back flow zone (in Italy, refer to
UNI 10683 point 6.5.8.)
• allow for maintenance of the chimney.

For dual flues (which should be spaced at least 2 m
apart), the chimney pot receiving the smoke from the
solid fuel appliance or that from the higher storey, must
be at least 50 cm higher than the other

AIR INTAKE FOR COMBUSTION

In general, we suggest two ways to ensure a proper
flow of combustion air. Air must come from the outside*
It is also important to ensure a change of heating air
and glass cleaning air etc.

Indirect air intake

The boiler stove takes air from the outside through the
hole on the rear.
Install an air outlet at floor level with an effective surface
area (net of the mesh or other protections) of at
least 80 cm

2

 (10 cm in diameter).

To prevent draughts, we recommend installing the
intake behind the product or behind a radiator.
Installing it in front of the appliance will create
unpleasant draughts.

Direct air intake**

Install an air intake of effective area (net of the mesh or
other protective equipment) at least equal to that of the
air intake at the back of the product.
Connect the air intake to the appliance’s air intake with
a tube (which may also be of the hose type). Increase
the diameter of the pipe if it is not smooth: assess its
pressure drops.
We recommend not exceeding a length of 3 m,
considering the draw of the flue. For each curve, up
to a maximum of two, the length must be reduced by
1 m. You should also consider increasing the diameter
of the pipe.

*The air may be drawn from an adjacent room only if:
• the flow is taken from permanent and unobstructed
openings communicating with the outdoors
• the air pressure in the adjacent room is never
lower than that of the outdoor pressure
• the adjacent room is not a garage. subject to fire
hazard, a bathroom or bedroom
• the adjacent room is not a shared room in the
condominium.

In Italy, UNI 10683 provides that ventilation is sufficient
even if a pressure difference between the outdoors
and indoors of no more than 4 PA is guaranteed (UNI
EN 13384-1). The installer who issues the declaration
of conformity is responsible for ensuring these
conditions.

**The direct connection of the air intake does not
make the product airtight. It is therefore necessary also
to ensure recovery of the air taken in the room by the
product (i.e. for the glass cleaning)

INSTALLER

INSTALLATION

Summary of Contents for MILLA H 12

Page 1: ...EN Installation use and maintenance page 2 MILLA H 12 PELLET BOILER STOVE...

Page 2: ...declaration DoP EK n 174a Moreover the company hereby declares that the wooden pellet boiler stoves MILLA H 12 comply with the requirements in the following European Directives 2014 35 UE Low Voltage...

Page 3: ...failure to follow the instructions in it could cause serious damage to the product and put the safety of those using it at risk OPERATING SEQUENCE follow the instructions for the operations described...

Page 4: ...ay become soiled the flue may catch fire and environmental damage may ensue cleaning the combustion chamber when hot DO NOT CLEAN THE HEARTH WITH A VACUUM CLEANER WHILE IT IS HOT You could damage the...

Page 5: ...5 ENGLISH DIMENSIONS MILLA H cm USER INSTALLER 110 56 56 4 3 52 39 24 16 6 8 cm smoke outlet 4 cm combustion air loading G 1 2 M return G 3 4 M delivery G 3 4 M 9 5 21 9 7 11 14 4 28 43 55...

Page 6: ...iameter 50 mm Weight with packaging 220 kg Energy efficiency classes 2015 1186 1187 Regulation A TECHNICAL DATA FOR SIZING THE FLUE which must in any case satisfy the requirements in this sheet and th...

Page 7: ...f and recycling them in a regulatory fashion UNPACKING The delivery consists of the following 3 packages one containing the stove s frame 1 one containing the claddings 2 one containing the claddings...

Page 8: ...THE PALLET WITHOUT HAVING OPENED THE COMBUSTION CHAMBER DOOR AND UNDONE THE SCREWS WHICH FIX IT TO THE PALLET THE DRAWINGS ARE FOR GUIDANCE ONLY USEFUL FOR THE INSTALLATION BUT THEY MAY NOT REFER TO...

Page 9: ...t of the stove must be directed differently depending on the objective heating radiators exchanger whether or not there is a puffer etc The material used in the circuit must be suitable to withstand a...

Page 10: ...tecnica THIS EDGE IDENTIFIES THE DIMENSION OCCUPIED BY THE PRODUCT ON THE LEFT SIDE see the technical manual ACQUA FREDDA COLD WATER 1 2 RITORNO RISCALDAMENTO HEATING RETURN 3 4 MANDATA RISCALDAMENTO...

Page 11: ...green light Pump in stand by mode Normal operation Steady red LED Stall Pump stalled Contact the TAC Contact winding Defective winding Flashing red LED Under over voltage Supply voltage too low high C...

Page 12: ...12 ENGLISH INSTALLATION EATING CONFIGURATION INSTALLER...

Page 13: ...13 ENGLISH INSTALLATION BOILER CONFIGURATION INSTALLER...

Page 14: ...14 ENGLISH INSTALLER INSTALLATION PUFFER CONFIGURATION...

Page 15: ...ne dialler for example 9 10 Probe for domestic hot water boiler N POLES POSSIBLE CONNECTIONS NOTES 1 2 3 Electrical connection for booster secondary pump Earth Neutral Phase 4 5 6 EXTERNAL SOLENOID VA...

Page 16: ...nt to UNI 10683 and UNI 7129 in the presence of gas fired products INSTALLATION Protection from heat and safety clearances The surfaces of the building that are adjacent to the product must be protect...

Page 17: ...at roof level with a proper chimney pot the flue may not discharge directly onto the wall or into an enclosed space even if the space in question is open to the sky be made of material with rated fire...

Page 18: ...ortant to ensure a change of heating air and glass cleaning air etc Indirect air intake The boiler stove takes air from the outside through the hole on the rear Install an air outlet at floor level wi...

Page 19: ...rical system must be compliant check the operation of the earth in particular Edilkamin is not responsible for malfunctions resulting from an improperly earthed system The power line must be of adequa...

Page 20: ...20 ENGLISH INSTALLER LINING Fig 1 Put the side A in this position Use the screws to fix it repeat for the other side Then put the top fig 1 A...

Page 21: ...ile it is operating and hence hot to the touch Make sure not to touch the smoke discharge pipe if hot FUEL Use UNI EN ISO 17225 2 category A1 wood pellets or similar regulatory products with the follo...

Page 22: ...erma il cursore passa al successivo ca Il giorno della settimana calcolato automaticamen Successivamente il display si posiziona sulla scher Set the values with the keys and confirm with OK The day of...

Page 23: ...a principale Nella barra di stato sono presenti i simboli delle richieste calore RISC e SANITARIO l eventuale attivazione della pompa e l ora Nell area principale la temperatura ambiente visualizzazio...

Page 24: ...s activated by the anti freeze mode level 1 if the probe temperature reads a temperature which is below the Anti freeze Setpoint The activation of the anti freeze both level 1 and level 2 is indicated...

Page 25: ...ture bottom number in the main area the power level represented by the flames the fan level represented by the filling in of the blades If the timer programming is active Crono the text TIMER appears...

Page 26: ...e STB The LCD shows the following information product mode STB the current time the room temperature or the mode of the room thermostat the activation of the timer programming if present Timer Crono O...

Page 27: ...tasto M fa accedere alla schermata Men By pressing the M button you access the Menu screen SPECIFICA TECNICA Nome Rev Data Pagina Dalla schermata di OFF si passa alla schermata di ON oppure di STAND...

Page 28: ...nu level Press ON OFF to quit without saving USER 8 Men Premendo il tasto M si accede al Men Pressione tasto scorro verso l alt Pressione tasto scorro verso il ba Pressione tasto OK entro nella voce d...

Page 29: ...perature you can move from one T to the next using When the arrow is on a number e g 16 you can increase decrease using USER SPECIFICA T Crono Il radiocomando consente la programmazione ora passo di 3...

Page 30: ...programmazione mi appare la sche tranne che per la scelta Singolo giorno per cui de Nella schermata di impostazione appare la progra impostazione multipla la programmazione quell Luned per 7Giorni e 5...

Page 31: ...ing functions to scroll through the days ahead to scroll through the days back OK return to the previous menu M return to the previous menu ON OFF return to the main screen SPECIFICA Visualizza Pressi...

Page 32: ...on the side of the display SPECIFICA TE Temperature Permette l impostazione della temperatura caldaia e dell accumulo Se attivata la sonda esterna perme climatica al posto della temperatura caldaia In...

Page 33: ...menu as indicated in the Menu section above press the M button Scroll using the buttons and select the function by pressing OK Use the buttons to activate deactivate the function Press M to quit witho...

Page 34: ...ss M to quit without saving Confirm by pressing the OK button for 2 seconds VARIOUS MENUS Data Ora I valori si modificano con i tasti e si conferm USER Info These readings should only be done when req...

Page 35: ...e to service the product properly will prevent it from working properly Any problems due to failure in servicing the stove will void the warranty Using the stove without cleaning the grate can cause t...

Page 36: ...ition the deflector after vacuuming D WEEKLY MAINTENANCE When the product is off and cold after having activated the cleaning brush as in routine maintenance you should vacuum the inspection plate und...

Page 37: ...Using non original spare parts may damage the appliance and relieves Edilkamin of all liability for damage that may arise from doing this Do not make unauthorised modifications DISPOSAL At the end of...

Page 38: ...ly There are two possibilities NO flame Check that the grate is seated properly and is clean Check that there are pellets in the tank and grate Use a piece of solid paraffin to light the stove contact...

Page 39: ...hnician H11 Switching OFF due to the inter vention of the safety pressure switch Ensure the stove and flue are clean Contact the technician H12 Room temperature probe failure Contact the technician H1...

Page 40: ...e serviced by an authorised Edilkamin technician WATER OVERHEATING SHUT DOWN WITHOUT ALARM If the water in the boiler stove reaches a temperature of 85 C the boiling stove shuts down without switching...

Page 41: ...41 ENGLISH...

Page 42: ......

Page 43: ......

Page 44: ...code 942028 GB 03 19 A w w w e d i l k a m i n c o m 942028 GB...