17. ADVICE FOR POSSIBLE PROBLEMS
In the event of problems, the product automatically performs the shutdown operation.
The display shows the reason (see below).
17.1. Display messages
MESSAGE
PROBLEM
ACTIONS
A01
It is shown if the combustion air intake flow rate
falls below a preset level
Check that the firebox door is closed
Check that regular maintenance has
been performed on the stove
Check that the smoke discharge and
combustion air intake duct are clean.
A02
It is shown if the motherboard does not detect
the correct smoke fan speed
Contact the technician
A03
It is shown if the thermocouple detects a
smoke temperature lower than a set value,
interpreting this as absence of flame
Check that there are enough pellets in
the hopper
Check that the water temperature has
not risen due to some valve being closed
(contact the technician)
Contact the technician
A04
It is shown if ignition is not successful within
the set time
Distinguish between the following two
cases:
The flame has NOT appeared:
Make sure that the crucible is in the
correct position and check that it is clean
Check for the presence of pellets in the
hopper and in the crucible
Try lighting with a solid ecological lighter
(contact the technician first and follow
the
instructions
of
the
lighter
manufacturer
very
carefully).
The
operation should be considered as a test
only, under the guidance of the
technician.
A05
Switch-off due to broken air flow rate sensor
Contact the technician
A06
It is shown if the electronic motherboard
detects that the smoke temperature probe is
broken or disconnected
Contact the technician
Summary of Contents for 812740-1139210
Page 16: ...16 6 4 ECODESIGN technical data Tera H 25...
Page 17: ...17...
Page 18: ...18 6 5 ECODESIGN technical data Tera H 30...
Page 19: ...19...
Page 33: ...33 Possible adjustments 10 Assemble the top with the ceramic 11 Tighten the screws...
Page 34: ...34 12 Open the door 13 Open the lower lid 14 Remove the lower lid...
Page 36: ...36 10 1 1 Possible adjustments...
Page 49: ...49 14 6 Ventilation if present Adjusting ventilation...
Page 54: ...54 14 9 4 Chrono prog To set the Chrono prog function...
Page 55: ...55 14 9 5 Chrono temp T1 T2 To set the target temperatures of the Chrono prog...
Page 56: ...56 14 9 6 Date and time To set the correct date and time...
Page 57: ...57 14 9 7 Language To select the display language...
Page 58: ...58 14 9 8 Display To adjust the brightness of the display background...
Page 61: ...61 14 9 10 Software These readings should only be done when requested by the technician...
Page 64: ...64 14 9 14 Pellet sensor To turn the pellet level sensor ON or OFF...
Page 66: ...66 14 9 16 airKare if present To activate or deactivate Airkare mode where present...
Page 72: ...72 If not performed correctly the operation of the product may be compromised...
Page 79: ...79...