13
Quantity
TERA H 30
Rated power
Reduced power
Output power
29,3
7,2
kW
Output power to water
24,7
5,1
kW
Yield
94,3
96,6
%
CO emissions at 13% O
2
0,007
0,006
%
Smoke temperature
124
64
°C
Fuel consumption
6,5
1,6
kg/h
Hopper capacity
45
kg
Draught
11,9
9,6
Pa
Autonomy
7
28
Hours
Water content
30
l
Expansion tank volume
12
l
Maximum operating pressure
3
bar
Maximum operating temperature
90
°C
Minimum volume of installation room
46
m
3
Heatable volume
765
m
3
Smoke duct diameter
100
mm
Air intake duct diameter
50
mm
Weight with packaging (ceramic)
250
kg
Energy efficiency class (Regulation
1185/2015)
A++
Environmental Class according to the
Italian Ministerial Decree 186
4 stars
Minimum distance of combustible
materials from Back/Side/Front
0/50/800
mm
Minimum distance of combustible
materials from Ceiling/Floor
NPD: (No declared
performance)
mm
NOTES ON THE TECHNICAL DATA
To calculate consumption, a heating value of 4.8 kW/Kg was used.
The heatable volume is calculated considering a heat demand of 33 Kcal/m³ per hour.
The autonomy may vary depending on the use/installation/fuel characteristics and it is not a contractual
obligation, nor is it a possible cause for dispute.
The product can work safety also with a higher draught. However, an excessive draught may result in switch-off
and/or decreased efficiency.
Summary of Contents for 812740-1139210
Page 16: ...16 6 4 ECODESIGN technical data Tera H 25...
Page 17: ...17...
Page 18: ...18 6 5 ECODESIGN technical data Tera H 30...
Page 19: ...19...
Page 33: ...33 Possible adjustments 10 Assemble the top with the ceramic 11 Tighten the screws...
Page 34: ...34 12 Open the door 13 Open the lower lid 14 Remove the lower lid...
Page 36: ...36 10 1 1 Possible adjustments...
Page 49: ...49 14 6 Ventilation if present Adjusting ventilation...
Page 54: ...54 14 9 4 Chrono prog To set the Chrono prog function...
Page 55: ...55 14 9 5 Chrono temp T1 T2 To set the target temperatures of the Chrono prog...
Page 56: ...56 14 9 6 Date and time To set the correct date and time...
Page 57: ...57 14 9 7 Language To select the display language...
Page 58: ...58 14 9 8 Display To adjust the brightness of the display background...
Page 61: ...61 14 9 10 Software These readings should only be done when requested by the technician...
Page 64: ...64 14 9 14 Pellet sensor To turn the pellet level sensor ON or OFF...
Page 66: ...66 14 9 16 airKare if present To activate or deactivate Airkare mode where present...
Page 72: ...72 If not performed correctly the operation of the product may be compromised...