background image

14

the pauses are not saved, then the resulting record 

will consist of recorded parts only (signal exceeds 

the threshold). These parts will be played one after 

another without interruption.

Configuring VAS

Voice  Activation  System  (VAS)  is  configured 

in the EMPlus program by changing two 

parameters:  VAS  threshold  level  and  VAS  time.

 

VAS level can be adjusted from 0 to -55 dB. 0 dB 

corresponds to very low sensitivity (the device 

records only very loud sounds) and the value of 

-55 dB to very high sensitivity (the slightest rustle 

is enough for the recorder to start recording). The 

best of VAS is achieved experimentally. You can 

start  by  setting  VAS  level  at  -  20  dB  (after  you 

have changed the settings, do not forget to press 

the  button  «Apply  changes  to  the  Recorder»). 

After disconnecting the recorder off the PC enable 

recording and place it in the conditions similar 

to the planned recording (for example, lecture 

in a classroom).  With the level of VAS properly 

configured, after the desired signal, the recorder 

switches to record mode which will be indicated 

by a LED flashing. If desired signal stops, and the 

VAS  time  is  up,  the  recorder  switches  to  Signal 

Standby mode.

Summary of Contents for EM Tiny+ Series

Page 1: ...loading from the B70 recorder 10 Setting Microphone Amplification for Tiny16 11 Timers 11 Voice Activation System VAS 12 Circular Recording 15 Charging and Battery Maintenance 16 Recorder Settings 17...

Page 2: ...on providing protection against fake records as well as unauthorized access to records The EMPlus program located in the built in memory is used to operate the recorder SoundProcessor program is desig...

Page 3: ...e PC the duration of pauses can be restored in the form of silence or deleted depending on the settings specified The recorder makes it possible to perform timer recording either daily with record sta...

Page 4: ...mware via USB port Technical Characteristics Signal to noise ratio for Tiny 65dB Signal to noise ratio for Tiny16 80dB Record Mode Mono Compression algorithms without compression uLaw Sampling rate fo...

Page 5: ...observe polarity marking on the recorder s case corresponds to the one on the battery Incorrect installation of battery may lead to malfunction which is not covered by the warranty repair Supplying p...

Page 6: ...chargeable battery charged and free memory capacity 1 flash states for 100 76 2 flashes 75 51 3 flashes 50 26 4 flashes 25 1 The interval between the first and second series of flashes is approximatel...

Page 7: ...at 8 kHz and for the recorders with batteries the autonomy is down by more than three times Fast switching during recording On Off On puts the tab which is visible in the Sound Processor program Thus...

Page 8: ...der Windows XP SP2 SP3 Vista 7 8 Newer versions are always available on the website http www ts market com 1 Connect USB adapter to the recorder then to the PC Red and green LEDs are briefly on the ad...

Page 9: ...the right one Do not disconnect the recorder while performing any operations in the EMPlus program This can cause data corruption during such operations the recorder s LED is flashing When the recorde...

Page 10: ...ery set Unzip the folder RMUsbDrv located in the recorder s memory If you have USB2 0 driver on your PC remove it using the RemoveOlddrivers exe program located in the folder RMUsbDrv in case you have...

Page 11: ...y silent ones Timers The recorder has two timers Daily and Once Timers enable recording to start automatically without user s control 1 When setting Once Timer you need to specify the record s start a...

Page 12: ...gh charge and as long as the timer is on 3 You can use both timers simultaneously but you should take into account that timer s operation times must not overlap or intersect Timer recording by can be...

Page 13: ...less than the preset threshold after some time VAS time the recorder stops recording sound into memory and only saves silence duration That continues until recording stops In case of signal level exc...

Page 14: ...very high sensitivity the slightest rustle is enough for the recorder to start recording The best of VAS is achieved experimentally You can start by setting VAS level at 20 dB after you have changed...

Page 15: ...d within the file will be divided into many pieces with the pauses in conversation for more than 1 second If you set 15 seconds after any knocking the recorder will continue recording silence for 15 s...

Page 16: ...3 hours while charging LED is flashing gradually with the interval of 5 seconds With maximum charging LED will continuously and smoothly change its brightness The user can recharge the rechargeable ba...

Page 17: ...ing records and files from the recorder to the PC Records playback before moving to the PC To configure the recorder connect it using the cable which is included into the delivery set and run the EMPl...

Page 18: ...rs at various settings Model Sample rate 8kHz 11kHz 16kHz 22kHz Tiny B70 10 8 7 5 Tiny B73 10 8 7 5 Tiny B74 35 20 14 12 Tiny B76 35 24 14 12 Tiny A77 58 55 45 30 Model Sample rate 8kHz 10kHz 13 3kHz...

Page 19: ...ently The recorder is unresponsive to the user s activity the rechargeable battery is discharged Leave the recorder connected to the PC After some time depending on the battery discharge level the PC...

Page 20: ...You forcedly enabled recording Synchronize the recorder s time with the PC In recorder settings untick Time synchronization with the PC Adjust the desirable timer and make record After connecting to t...

Reviews: