LMD222 and LMD224 Series
Operations Manual
Eberle Design Inc.
Page 10
4.6 RESPONSE TIMING
This table assumes that all channels are set to the same Sensitivity Level.
4.6.1 LMD222 SERIES RESPONSE TIMING
Sensitivity Level
Response
Sensitivity Level
Response
9
40 +/- 15ms
4
3 +/- 1ms
8
19 +/- 7ms
3
3 +/- 1ms
7
10 +/- 3ms
2
3 +/- 1ms
6
5 +/- 1.5ms
1
3 +/- 1ms
5
3.2 +/- 1ms
--
--
4.6.2 LMD224 SERIES RESPONSE TIMING
Sensitivity Level
Response
Sensitivity Level
Response
9
162-217 ms
4
11-16 ms
8
77-102 ms
3
11-16 ms
7
38-51 ms
2
11-16 ms
6
21-28 ms
1
11-16 ms
5
12-18 ms
--
--
4.7 LMD222 CONNECTOR PIN ASSIGNMENTS
Pin
Function
Pin
Function
A
Logic Ground
1
Reserved
B
Detector Unit DC Supply
2
Reserved
C
External Reset
3
Reserved
D
Channel 1 Loop Input
4
Channel 1 Redundant Loop Input
E
Channel 1 Loop Input
5
Channel 1 Redundant Loop Input
F
Channel 1 Output (+)
6
Reserved
H
Channel 1 Output (-)
7
Reserved
J
Channel 2 Loop Input
8
Channel 2 Redundant Loop Input
K
Channel 2 Loop Input
9
Channel 2 Redundant Loop Input
L
Chassis Ground
10
Reserved
M
Reserved
11
Reserved
N
Reserved
12
Reserved
P
Reserved
13
Reserved
R
Reserved
14
Reserved
S
Reserved
15
Reserved
T
Reserved
16
Reserved
U
Reserved
17
Reserved
V
Reserved
18
Reserved
W
Channel 2 Output (+)
19
Reserved
X
Channel 2 Output (-)
20
Reserved
Y
Reserved
21
Reserved
Z
Reserved
22
Reserved
Pin 1 through 22 is on the top (component) side and pin A through Z is on the bottom
(solder) side. Polarization keys are located at three positions:
Between B/2 and C/3
Between M/11 and N/12
Between E/5 and F/6
4.8 LMD224 CONNECTOR PIN ASSIGNMENTS
Pin
Function
Pin
Function
A
Logic Ground
1
Reserved
B
Detector Unit DC Supply
2
Reserved