EdgeMarc 4576 Enterprise Session Border Controller Installation Guide
7
Elevated Operating Ambient
- If installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment may be greater than room
ambient. Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature specified by the
manufacturer.
Reduced Air Flow
- Installation of the equipment in a rack should be such that the
amount of airflow required for safe operation of the equipment is not compromised.
Mechanical Loading
- Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading
- Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might
have on overcurrent protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Earthing
- Reliable earthing of rack-mounted equipment should be
maintained. Particular attention should be given to supply connections other than
direct connections to the branch circuit (e.g. use of power strips).
To install the EdgeMarc in a rack:
1. Attach the rack mount ears to both sides of the EdgeMarc chassis with the
supplied screws.
2. Install the chassis in the rack with rack mount screws (not included).
Step 2: Connect to the LAN and WAN