PROBLEM
POSSIBLE CAUSE
REMEDY
The door will not
close properly.
•
The appliance is not properly level.
•
The door was reversed and not
properly installed.
•
The gasket is dirty.
•
The shelves are out of position.
•
Level the appliance with the
adjustable feet.
•
Check the door hinge and
reassemble correctly.
•
Clean the door gasket.
•
Check the shelves and refit
correctly.
Display shows an
error code
•
“E1” indicates that the air
temperature sensor is open circuit.
•
“E2” indicates that the air
temperature sensor is short circuit.
•
“E3” indicates that the defrost sensor
in the evaporator is short circuit.
•
“E4” indicates that the defrost sensor
in the evaporator is open circuit.
•
“E6” indicates a solenoid valve
failure.
•
“E7” indicates a door switch failure.
•
Call for service.
The alarm sounds
and the
temperature
display flashes.
Has the appliance door been open
for longer than 60 seconds? If not,
then the temperature has risen
higher or fallen lower than the
temperature that has been set. This
could be due to:
•
The appliance door being opened
too often.
•
The ventilation opening being
covered or too dusty.
•
A lengthy interruption to the power
supply. large number of bottles has
been added to the unit.
•
If yes, close the door.
•
Do not open the door more often
than necessary.
•
Clear the obstructions and clean
the dust.
•
Leave the appliance to work for a
while until the set temperature has
been reached.
The icon “--” is lit
up and flashing in
the temperature
display
•
The display temperature is out of the
range.
•
Only temperatures within the range
0~99°F/-9~37°C the appliance can
display will be shown. If the
temperature is not within this
range, the icon “--” will be
displayed instead. That is normal.