background image

EdgeStar Portable Dehumidifier  

 

10 

Maintenance 

continued

 

 
If you are not going to be using the unit for an extended period of time, 

follow the instructions below before storing your unit: 

 

1.

 

Turn the unit off, unplug and wait 24 hours before emptying the 

water bucket to allow for excess moisture to drain into the bucket. 

2.

 

Drain all water from the water tank.  

3.

 

Clean the air filter, water tank and unit. 

4.

 

Unplug and carefully wind the power cord. 

5.

 

Cover the unit with a plastic bag. 

6.

 

Store the unit in an upright position in a dry, well-ventilated place. 

 

 
When the unit is operated in temperatures below 54°F the surface of the 

evaporator may accumulate a layer of frost which will reduce the 
efficiency and effectiveness of the dehumidifier.  When this occurs, the 

unit will automatically activate its auto-defrost feature.  The time required 

to complete the auto-defrost cycle varies and is dependent on the 
ambient temperature and relative humidity of the operating environment.  

The auto-defrost indicator located on the control panel will light up when 

the auto-defrost feature is running.   
 

Note: Do not operate this dehumidifier in temperatures below 41°F 

 

Energy Saving Guide 

 

Read and follow the below energy saving tips to get the best 
performance and efficiency from your portable dehumidifier: 

 

Do not cover the air outlet (exhaust) while in use. 

 

Do not place the unit in front of curtains or drapes - to ensure they do 
not obstruct the air intake. 

 

Keep curtains, blinds or drapes closed during the sunniest part of the 

day. 

 

Close all windows and doors. 

 

Indoor relative humidity should ideally be kept between 35 and 60 

percent depending on the ambient temperature. 

 

Make sure the unit is on a level surface. 

 

To prolong the compressor's life, please wait at least 3 minutes before 

turning the unit back on after shutting it off. 

 

Inspect and keep the pre-filter clean by cleaning regularly. 

 

Perform routine maintenance. 

Preparation for Storage 

Auto-Defrost 

Summary of Contents for DEP700WP

Page 1: ...Dehumidifier Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com Model DEP700WP...

Page 2: ...sounds emits smells or smoke comes out of it and contact customer service Do not remove any part of the casing unless instructed by an authorized technician You should never attempt to repair the unit...

Page 3: ...N SPEEDS 5 SETTING THE HUMIDITY LEVEL 5 LCD DISPLAY 6 Temperature and Timer Display 6 Humidity Level Display 6 Error Codes 6 WATER FULL LIGHT 6 ADDITIONAL NOTES ABOUT THE DEHUMIDIFIER S BEHAVIOR 6 DRA...

Page 4: ...Your Records Please write down the model number and serial number below for future reference Both numbers are located on the ratings label on the back of your unit and are needed to obtain warranty s...

Page 5: ...EdgeStar Portable Dehumidifier 2 Parts Identification Back View Front View Water Level Indicator Water Bucket Air Intake Control Panel Handle Exhaust Gravity Drain Outlet Casters Pump Drain Outlet...

Page 6: ...the unit and at least 20 inches of space above the unit If you have multiple power outlets in the room choose one that is near the dehumidifier and that will be able to provide adequate power to the...

Page 7: ...ter bucket is full and must be emptied Timer Lights up to indicate that the unit is in timer mode High Speed Lights up to indicate the fan is on the high setting Normal Speed Lights up to indicate the...

Page 8: ...mately 10 seconds before reverting back to displaying the current temperature 5 To cancel or turn off the timer setting adjust the increments by using the Increase and Decrease buttons until 0 hours i...

Page 9: ...ambient temperature is suitable for the unit 41 F 95 F If the ambient temperature is suitable please contact customer service HI Temperature too high error Current room temperature is above 122 F Make...

Page 10: ...ed properly 3 Place the other end of the drain hose in a floor drain or other suitable drainage port 4 Operate unit in normal manner 5 To remove pump drain line press the release button located direct...

Page 11: ...the continuous gravity drain you will need to supply a suitable drain hose You may use a standard garden hose with a connector fitting 1 Locate the gravity drain hose port found on the back of the un...

Page 12: ...ater bucket and then remove the pre filter as shown below 2 Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt then rinse thoroughly under lukewarm running water below 104 F...

Page 13: ...varies and is dependent on the ambient temperature and relative humidity of the operating environment The auto defrost indicator located on the control panel will light up when the auto defrost featu...

Page 14: ...y dehumidifier is not functioning at all Unit is not receiving power Make sure the unit is plugged in Insufficient power Move the unit to another outlet Check your circuit breaker Refer to the rating...

Page 15: ...ve a faulty control panel Restart the unit and if issue persists contact customer service Unit has an E1 Error Temperature sensor error Restart the unit and if issue persists contact customer service...

Page 16: ...Model DEP700WP Voltage Frequency AC 115V 60Hz Power Consumption 862W Operating Current 7 5A Water Bucket Capacity 8 5 Liters 2 25 Gallons Dehumidifying Capacity 80F RH60 70 Pints Day Refrigerant R410...

Page 17: ...ruct in proper usage of the product Damages or operating problems resulting from misuse abuse operation outside environmental specifications uses contrary to instructions provided in the owner s manua...

Page 18: ...service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edge...

Reviews: