Operating the Control Panel 

 

Use the 

 

Power button to turn the portable dehumidifier on and 

off. The LED i

ndicator next to “Power” will light up. By default when 

you first use the power button, the unit will begin to operate in 
normal fan speed mode.  
 
Note: If the unit was powered off, wait at least 3 minutes before 
powering it back on. 
 

Auto-Restart:

 

If power to the unit is interrupted, the dehumidifier 

will restart itself in with the last used mode/settings once the power 
is restored. The compressor will restart after 3 minutes. 
 

Auto-Shut Off:

 The unit will shut off when the set humidity has 

been reached, or when the water bucket is full, has been removed, 
or is not in its proper position. 
 
Continuous mode dehumidifies the air until the water bucket is full. 
Use the continuous mode for maximum dehumidification. You will 
not be able to use the set humidity buttons.  
 
To operate the unit in continuous mode: 
1) Make sure the power cord is plugged into a power outlet. 

2) Press the 

 

Power button. 

3) Press the 

 

Continuous button. The LED indicator next to 

“Continuous” will light up. 
4) Select the fan speed by using the 

 

Normal or 

 

High 

button. 
 
The dehumidifier has two fan speeds. Use the high fan speed for 
maximum moisture removal. Use the normal fan speed for quieter 
operation. 
 

Select the fan speed by using the 

 

Normal or 

 

High button. 

 
The desired humidity level can be set within a range of 35% 
Relative Humidity (RH) to 80% RH in 5% increments.  
 
To set the desired humidity level percentage:  
1) Make sure the power cord is plugged into a power outlet. 

2) Press the 

 Power button. Make sure the continuous light is 

turned off. 

3) Press the 

 Increase and 

 Decrease buttons to set the 

desired humidity level. After a few seconds, the LCD display will 
revert to the actual room humidity level with ±5% accuracy. For 

drier air use the 

 Decrease button. 

 

Power 

Continuous Mode 

Fan Speeds 

Setting the Humidity Level 

Note: 

Relative Humidity (RH) 

is the ratio of the actual water 
content of the air at a given 
temperature to the potential 
water content at that same 
temperature. 

 

Summary of Contents for DEP400EW-1

Page 1: ...Dehumidifier Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com Models DEP400EW 1 DEP650EW 1 DEP700EW 1...

Page 2: ...ge sounds emits smells or smoke comes out of it and contact customer service Do not remove any part of the casing unless instructed by an authorized technician You should never attempt to repair the u...

Page 3: ...Shut Off 5 CONTINUOUS MODE 5 FAN SPEEDS 5 SETTING THE HUMIDITY LEVEL 5 LCD DISPLAY 6 Error Codes 6 WATER FULL LIGHT 6 ADDITIONAL NOTES ABOUT THE DEHUMIDIFIER S BEHAVIOR 6 DRAINING THE UNIT 7 MANUAL D...

Page 4: ...write down the model number and serial number below for future reference Both numbers are located on the ratings label on the back of your unit and are needed to obtain warranty service You may also w...

Page 5: ...anel Handle Pre filter Exhaust Drain hose outlet Caster wheels Power plug All the pictures in this manual are for reference only Your unit may be slightly different than the images depicted Water Leve...

Page 6: ...above the unit 10 10 10 10 If you have multiple power outlets in the room choose one that is near the dehumidifier and that will be able to provide adequate power to the unit See the power requirement...

Page 7: ...ion Power Lights up when the unit is turned on Continuous Lights up when the unit is set to run continuously until the water bucket is full High The High Fan Speed indicator light will be lit when you...

Page 8: ...he power cord is plugged into a power outlet 2 Press the Power button 3 Press the Continuous button The LED indicator next to Continuous will light up 4 Select the fan speed by using the Normal or Hig...

Page 9: ...nit time to defrost The error will clear itself after the unit has been defrosted P2 Bucket is full Empty the water bucket and reinstall it The Water Full Light will illuminate when the bucket is read...

Page 10: ...onnector You can use a 12 mm hose to attach to the connector 2 Remove the rubber plug from the back of the unit s drain hose outlet and push the drain hose through 3 Securely attach the drain hose to...

Page 11: ...effectiveness If the unit is used in a dusty environment you may need to clean it on a weekly basis To clean the pre filter follow the steps below 1 Power off the unit and remove the pre filter 2 Use...

Page 12: ...d 60 percent depending on the ambient temperature Make sure the unit is on a level surface To prolong the compressor s life please wait at least 3 minutes before turning the unit back on after shuttin...

Page 13: ...nit may have been shipped on its side Shut off the unit Let the unit sit on a level surface for at least 24 hours and restart Damaged compressor Contact customer service My dehumidifier is leaking A d...

Page 14: ...Model DEP650EW 1 Voltage Frequency AC 115V 60Hz Power Consumption 710W Operating Current 6 7A Water Bucket Capacity 10 Liters 2 64 Gallons Dehumidifying Capacity 80F RH60 65 Pints Day Coolant R410A Di...

Page 15: ...product or to instruct in proper usage of the product Damages or operating problems resulting from misuse abuse operation outside environmental specifications uses contrary to instructions provided in...

Page 16: ...edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edgestar com...

Reviews: