Maintenance 

continued

 

 

If you are not going to be using the unit for an extended period of time, 
follow the instructions below before storing your unit: 
 
1) Turn off the unit and wait 24 hours before emptying the water tank. 
2) Drain all the water from the water tank.  
3) Clean the air filter, water tank and unit. 
4) Unplug and carefully wind the power cord. 
5) Cover the unit with a plastic bag. 
6) Store the unit in an upright position in a dry, well-ventilated place. 

Energy Saving Guide 

 

Read and follow the guide below to get the best performance and 
efficiency from your portable dehumidifier: 

  Do not cover the air outlet (exhaust) while in use. 

  Do not place the unit in front of curtains or drapes- to ensure they do 

not obstruct the air intake. 

  Keep curtains, blinds or drapes closed during the sunniest part of the 

day. 

  Close all windows and doors. 

  Indoor relative humidity should ideally be kept between 35 and 60 

percent depending on the ambient temperature. 

  Make sure the unit is on a level surface. 

  To prolong the compressor's life, please wait at least 3 minutes before 

turning the unit back on after shutting it off. 

  Inspect and keep the pre-filters clean by cleaning regularly. 

  Perform routine maintenance. 

Troubleshooting 

Follow the troubleshooting chart to resolve common issues. 

Issue 

Possible Cause 

Solution 

My dehumidifier does not 
dry the air 

Insufficient time to dry 

Run the unit for a longer 
period of time 

Air intake or Exhaust 
vents are blocked 

Make sure there are no 
towels, curtains, or 
furniture blocking the 
front and back of the unit 

Humidity control may not 
be set low enough 

Lower the humidity 
control. Run the unit in 
continuous mode 

Opened windows or 
doors 

Close all windows and 
doors 

Room temperature is too 
low (below 41ºF) 

Increase the room 
temperature 

There is a kerosene 
heater or something 
giving off water vapor in 
the room 

Remove any device 
producing water vapor 

Frost appears on the 
coils 

This is normal behavior 

The dehumidifier has an 
auto-defrost feature 

Preparation for Storage 

Summary of Contents for DEP400EW-1

Page 1: ...Dehumidifier Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com Models DEP400EW 1 DEP650EW 1 DEP700EW 1...

Page 2: ...ge sounds emits smells or smoke comes out of it and contact customer service Do not remove any part of the casing unless instructed by an authorized technician You should never attempt to repair the u...

Page 3: ...Shut Off 5 CONTINUOUS MODE 5 FAN SPEEDS 5 SETTING THE HUMIDITY LEVEL 5 LCD DISPLAY 6 Error Codes 6 WATER FULL LIGHT 6 ADDITIONAL NOTES ABOUT THE DEHUMIDIFIER S BEHAVIOR 6 DRAINING THE UNIT 7 MANUAL D...

Page 4: ...write down the model number and serial number below for future reference Both numbers are located on the ratings label on the back of your unit and are needed to obtain warranty service You may also w...

Page 5: ...anel Handle Pre filter Exhaust Drain hose outlet Caster wheels Power plug All the pictures in this manual are for reference only Your unit may be slightly different than the images depicted Water Leve...

Page 6: ...above the unit 10 10 10 10 If you have multiple power outlets in the room choose one that is near the dehumidifier and that will be able to provide adequate power to the unit See the power requirement...

Page 7: ...ion Power Lights up when the unit is turned on Continuous Lights up when the unit is set to run continuously until the water bucket is full High The High Fan Speed indicator light will be lit when you...

Page 8: ...he power cord is plugged into a power outlet 2 Press the Power button 3 Press the Continuous button The LED indicator next to Continuous will light up 4 Select the fan speed by using the Normal or Hig...

Page 9: ...nit time to defrost The error will clear itself after the unit has been defrosted P2 Bucket is full Empty the water bucket and reinstall it The Water Full Light will illuminate when the bucket is read...

Page 10: ...onnector You can use a 12 mm hose to attach to the connector 2 Remove the rubber plug from the back of the unit s drain hose outlet and push the drain hose through 3 Securely attach the drain hose to...

Page 11: ...effectiveness If the unit is used in a dusty environment you may need to clean it on a weekly basis To clean the pre filter follow the steps below 1 Power off the unit and remove the pre filter 2 Use...

Page 12: ...d 60 percent depending on the ambient temperature Make sure the unit is on a level surface To prolong the compressor s life please wait at least 3 minutes before turning the unit back on after shuttin...

Page 13: ...nit may have been shipped on its side Shut off the unit Let the unit sit on a level surface for at least 24 hours and restart Damaged compressor Contact customer service My dehumidifier is leaking A d...

Page 14: ...Model DEP650EW 1 Voltage Frequency AC 115V 60Hz Power Consumption 710W Operating Current 6 7A Water Bucket Capacity 10 Liters 2 64 Gallons Dehumidifying Capacity 80F RH60 65 Pints Day Coolant R410A Di...

Page 15: ...product or to instruct in proper usage of the product Damages or operating problems resulting from misuse abuse operation outside environmental specifications uses contrary to instructions provided in...

Page 16: ...edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edgestar com...

Reviews: