background image

 
 

19 

 
 

 

 

 

Summary of Contents for AP16000G

Page 1: ...ar com Warranty service should be performed by an authorized service representative only SERVICE MANUAL Large Room 220V Portable Single Hose Air Conditioner MODEL AP16000G Document Type Service Manual Version V1 0 04132018 CAUTION READ ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE SERVICING THE UNIT ...

Page 2: ...SYSTEM DIAGRAM 10 6 MODES AND OPERATING CONDITIONS 11 6 1 TEMPERATURE PARAMETERS INDOOR 11 6 2 COOLING MODE 11 6 3 DRY MODE 11 6 4 FAN MODE 11 6 5 AUTO MODE 12 6 6 TIMER MODE 12 6 7 SLEEP MODE 12 6 8 FREEZE PREVENTION MODE 12 6 9 COMPRESSOR PROTECTION MODE 12 6 10 OVERFLOW PREVENTION MODE 12 7 TROUBLESHOOTING 13 7 1 TROUBLESHOOTING GUIDE 13 7 2 ERROR CODES 14 8 UNIT DISASSEMBLY 16 ...

Page 3: ... may occur Common sense caution and care must be exercised To prevent electric shock always unplug an appliance from the power supply before attempting any service Disconnect the power cord by grasping the plug not the cord Do not bypass cut or remove the grounding plug Prevent water from spilling onto electric elements or the machine parts Always refer to the rating label on the appliance for rat...

Page 4: ...liance is properly grounded Do not bypass cut or remove the grounding plug If the power cord is damaged it must be replaced by the manufacturer or a qualified technician Do not use extension cords or power strips with this unit You may need to contact an electrician if it is necessary to use a longer cord or if you do not have a properly grounded outlet Do not modify the power cord s length or sha...

Page 5: ... exposed to the weather Disconnect from the power socket before cleaning or maintenance If the plug power cord is damaged it must be replaced by the manufacturer or an authorized service representative This machine shall be repaired only by an authorized service representative Only genuine replacement parts should be used If connected to a circuit protected by fuses use time delay fuses with this ...

Page 6: ...n Area yd2 19 1 28 7 Climate Type T1 Isolation I Moisture Protection IPX0 Permissible Excessive Operating Pressure for the Discharge Side PSIG 551 Permissible Excessive Operating Pressure for the Suction Side PSIG 174 Throttling Method Capillary Defrosting Method Fuse A 3 15 Operation Temp ºF 60 8 86 Ambient Temp Cooling ºF 60 8 95 Ambient Temp Heating ºF Sound Pressure Level H M L dB A 57 55 53 S...

Page 7: ... RLA A 0 28 Fan Motor Capacitor µF 2 Form Aluminum Fin copper Tube Pipe Diameter inch ĭ1 4 5RZ Q DS inch 3 1 5 8 Coil Length LXDXW inch 14 5 16X1 1 2X11 1 4 Swing Motor Model MP28GA Output of Swing Motor W 2 Fan Type Centrifugal Condenser Fan Diameter inch 8 9 16 Form Aluminum Fin copper Tube Pipe Diameter inch ĭ1 4 5RZV Q DS inch 4 1 5 8 Coil Length LXDXW inch 13 3 4X13 3 4X2 Fan Motor Speed rpm ...

Page 8: ...7 2 Exploded View and Parts List ...

Page 9: ...Sub Assembly 15 Capacitor CBB61S 50 Water Level Switch Base 16 Capacitor CBB61S 51 Water Level Switch 17 Electric Box Cover 52 Water Tray Sub Assembly 18 Main Board 53 Water Tray 19 Foam Propeller Housing 54 Castors 20 Gear Sub Assembly 55 Motor Sub Assembly Flinger 21 Centrifugal Fan 56 Flinger Draw Water Motor 22 Guide Louver 1 57 Water Flywheel 23 Guide Louver 2 58 Remote Controller 24 Diversio...

Page 10: ...9 3 Wiring Diagram ...

Page 11: ...play board connectors 7 Water level switch connector 8 Condenser temperature sensor connector 9 Room ambient temperature sensor connector 10 Frost sensor connector 11 NA for this model 12 Louver Stepping motor connector 13 Flinger Draw water motor connector 14 Condenser fan connector 15 NA for this model 16 Evaporator fan connector ...

Page 12: ...top while the indoor fan operates at the set fan speed When Tpreset 1ºC 2ºF Tamb Tpreset 1ºC 2ºF the unit stays in its current operating mode Under cooling mode the temperature can be set between 61 and 86ºF 16 30ºC 6 3 Dry Mode Under this mode the set temperature and ambient temperature won t be displayed The indoor fan operates at low fan speed The compressor and outdoor fan operate continuously...

Page 13: ...to enter sleep mode The Sleep Mode can be activated when in Cool Mode or Heat Mode and will not operate when in Fan Mode When operating in Cool Mode the Sleep function will slowly raise the Temp Control by 4 Fahrenheit over the initial 2 hour Sleep Mode period When operating in Heat Mode AP13500HG only the Sleep function will slowly lower the Temp Control by 4 Fahrenheit over the initial 2 hour Sl...

Page 14: ...if defective Poor cooling or heating performance Room temperature is below 61ºF 16ºC or above 86ºF 30ºC Cooling will not occur until room temperature rises above 61ºF 16ºC Heating will not occur until room temperature falls below 86ºF 30ºC Fan speed is set too low Increase fan speed to improve air flow Set temperature is too high or too low Set to a Lower or higher temperature Filter is dirty Clea...

Page 15: ...ce sensor Sensor is defective Replace sensor Main PCB is defective Replace PCB F2 LED blinks twice then off for 3 seconds Evaporator temperature sensor is open short circuited Sensor connection is loose or disconnected Reconnect any loose or disconnected wires Sensor wire is damaged Repair wire or replace sensor Sensor is defective Replace sensor Main PCB is defective Replace PCB F4 LED blinks fou...

Page 16: ...s then off for 3 seconds Overload malfunction Unstable power supply voltage or supply voltage too low Requires certified electrician to adjust supply voltage to within proper operating parameters The coils are dirty or the air inlet or outlet is blocked Clean coils and or move remove obstructions Fan is not running or set too low Increase fan speed or replace fan if defective Compressor is defecti...

Page 17: ...16 8 Unit Disassembly ...

Page 18: ...17 ...

Page 19: ...18 ...

Page 20: ...19 ...

Page 21: ...20 ...

Page 22: ...21 ...

Page 23: ...ll St Suite 1800 Austin TX 78754 support edgestar com service edgestar com edgestar com Warranty service should be performed by an authorized service representative only DATE REVISION NOTES 04 13 2018 INITIAL DOCUMENT ...