background image

15 

 

Maintenance – Cleaning the Unit 

 
Always unplug the air conditioner from the power outlet before cleaning. Clean 
the air conditioner regularly to maximize performance and efficiency. 
 

Cleaning the unit 

Use a soft damp cloth to wipe the body clean. 
Use a soft bristle brush to clean between the control panel’s buttons. 
Never use abrasive chemicals, gasoline, detergents, chemically treated cloths, or other 
cleaning solvents that may damage the cabinet exterior.  

 

Cleaning the pre-filter 

Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt, then rinse 
thoroughly under warm running water that is not hotter than 104

o

 F. Dry thoroughly 

before replacing. 
 

Note:

 The activated carbon filter is not washable- replace it as needed. Contact 

EdgeStar retailers for replacement filters. 
 

Warning:

 Never operate the unit without the filters. 

 

Follow the instructions below to prepare your product for storage. 

 

 

 

1.  Drain all the water from the unit 

before storing.  Operate the unit in 
fan mode for a few hours to 
thoroughly dry the inside. 

2.  Clean or change the filter. 

3.  Unplug and store the power cord 

as shown. 

4.  Replace the unit in the original 

carton, or cover it before storing 
away. 

 

 FIG.20

 

 

Preparation for Storage 

Cord 

Summary of Contents for AP10000HW

Page 1: ...Portable Air Conditioner Owner s Manual This owner s manual provides instructions on safe installation use and maintenance Please read it carefully and save it for reference AP10000HW...

Page 2: ...ned for indoor use only 2 Do not use the unit in extremely humid or wet environments 3 Do not wet the housing or control panel 4 Do not pull the unit by the cord 5 Always turn the unit off and unplug...

Page 3: ...aust Hose Installation 8 Operation Using the Control Panel 10 Using the Remote Control 12 Adjusting the Louvers 12 Maintenance Water Drainage 13 Extending the Drain Tube 14 Cleaning the Unit 15 Prepar...

Page 4: ...4...

Page 5: ...eded to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warranty Model Number ____________...

Page 6: ...rage 8 Air pre filter 9 Air inlet evaporator 10 Exhaust air outlet 11 Air inlet condenser 12 Water stopper drainage point Accessories 13 Flat adapter for insertion over hose and into window kit 14 Exh...

Page 7: ...the unit 2 Remove the activated carbon filter from its plastic bag 3 Place the activated carbon filter on the back of the unit 4 Install the pre filter frame to the unit Note Replace the activated ca...

Page 8: ...ross so that the kit is held securely You may need to adjust the size of the window kit and secure it with screws This technique may also be used for sash windows Note Take care to secure your window...

Page 9: ...to work less efficiently Improper setup may cause the unit to overheat and shut off Figs 8 9 show the correct position The hose may be extended from 11 to 59 For maximum efficiency use the shortest l...

Page 10: ...g Between Automatic Cooling Heating or Fan Mode Press the MODE button to select the desired mode automatic cooling heating or fan The indicator of your selected mode comes on Control Panel Parts FIG 1...

Page 11: ...of hours you want to wait for the machine to shut off automatically You are able to set the time between 1 to 12 hours by continuing to press the Timer button The timer indicator will light on When th...

Page 12: ...you press any of the buttons 2 Power Button Used to power the unit on or off 3 Mode Button Used to change between auto cooling heating or fan modes 4 Timer Button Used to set the timer function 5 Up B...

Page 13: ...osition a container a water tray for example underneath the drain hole 3 Remove the drain cap rubber plug from the drain hole and allow the water to drain out 4 When the container is almost full repla...

Page 14: ...level 2 Flashing Comp Water indicator will not function in this mode of drainage 3 This unit will not shut off when an external drain pan tray is filled 4 If you want to extend the water tube you can...

Page 15: ...the filter lightly to remove loose dust and dirt then rinse thoroughly under warm running water that is not hotter than 104o F Dry thoroughly before replacing Note The activated carbon filter is not w...

Page 16: ...room before you arrive You may want to operate the unit all day if you live in a warmer climate 7 Minimize the heat sources direct sunlight computers servers people etc in the room 8 Close all window...

Page 17: ...t servers etc 5 Run the unit before it is needed For example run the unit in the morning before the area gets hot and continue to run the unit all day long in order to maintain a low temperature 6 Use...

Page 18: ...15 V 60 Hz Power Ampere Consumption for cooling 830W 7 9 A Power Ampere Consumption for heating 920W 8 2 A Maximum Dehumidifying Capacity 50 pints day Refrigerant R22 15 2 OZ Fan speeds 2 High and Low...

Page 19: ...ail in basis to EdgeStar s authorized repair facility during the first 90 days from the date of original purchase All defective product components covered by this warranty will be repaired or replaced...

Page 20: ......

Page 21: ...or product guides additional troubleshooting resources and up to date information visit us on the web at http www edgestar com EdgeStar Products Box 81336 Austin TX 78708 1336 Toll Free 1 866 319 5473...

Reviews: