Edge Lighting PSB-30-12VDC Installation Instructions Manual Download Page 7

27: 

Replace the DVR-RGB-60 cover.

28: 

Replace the power supply cover and secure it by tightening 

      the six Phillips screws.

7

Q

19

18

18: 

Connect the white power supply wire marked "+" to 

      DVR-RGB-60 "Vdc+" red terminal.

19:

 Connect the black power supply wire marked "-" to 

      DVR-RGB-60 "Vdc-" blue terminal.

20: 

Use the "Low Voltage Wire Size Chart" on page 1 to 

      determine proper wire size connecting to the DVR-RGB-60
      terminals. 

21: 

Run the proper size green, red, blue, and black wires from 

      the RGB LED soft strip to the power supply case.

22: 

Run the proper size green, red, blue, and black wires from 

      the RGB LED soft strip to the power supply case.

23: 

Connect the black wire into DVR-RBG-60 "LED " 

      white terminal. Connect the other end to RGB soft strip 
      black wire(s).

24:

 Connect the red wire into DVR-RBG-60 "Group 1-" red  

      terminal. Connect the other end to RGB soft strip red 
      wire(s).

25: 

Connect the green wire into DVR-RBG-60 "Group 2-" green 

      terminal. Connect the other end to RGB soft strip green 
      wire(s).

26: 

Connect the blue wire into DVR-RGB-60 "Group 3-" blue 

      terminal. Connect the other end to RGB soft strip red 
      wire(s).

NOTE: 

Use only 12 volt LED RGB soft strip with this power 

supply.

R

LED SOFT STRIP

23

24

21

NOTE:

 

The DVR-RGB-60 terminals adapt maximum 18 AWG 

size. To avoid voltage drop, use 6" of 18 AWG size in RGB 
terminals connected inline to proper size gauge wire attached 
to the RGB LED wires with wire nuts. See the "Low Voltage 
Wire Size Chart" on page 1.

25

26

S

COVER

0-10V

Dimming

LED +

LED -

L   N   G

PHILLIPS SCREW

28

"N" White

"L" Black

"  " GREEN

White +

Black -

M

CONDUIT

NOTE: 

This power supply is for multiple runs.

 

Do not exceed 

the maximum wattage of the power supply.

Summary of Contents for PSB-30-12VDC

Page 1: ...r to the electrical box off during installation Read the Important Safety Instructions before installation NOTE To avoid overheating the power supply install it in a ventilated remote location where a...

Page 2: ...ower supply case 4 Run the line voltage power wires from the panel to the power supply case 1 POWER SUPPLY ELECTRICAL BOX CONDUIT 2 4 2 LIGHT SWITCH COVER PHILLIPS SCREW CASE 5 Connect the hot power w...

Page 3: ...upply wire marked to black conduit wire going to soft strip 13 Connect the red conduit wire to red soft strip wire s with a wire nut 14 Connect the black conduit wire to black soft strip wire s with a...

Page 4: ...ure Cap the yellow controller wire with a wire nut For three way switching refer to the instructions provided with the controller H LINE VOLTAGE WIRES LIGHTOLIER ZP600FAM120 CONTROLLER 6 Run the line...

Page 5: ...ip to be connected to power supply before re feeding is 16 of SS1 or 8 of SS3 NOTE Use only 12 volt LED soft strip with this power supply 5 18 17 16 L COVER 0 10V Dimming LED LED L N G PHILLIPS SCREW...

Page 6: ...T in EXT in VDC VDC DMX in DMX in DMX in shield LEDSync out LEDSync out LEDSync out shield 12 CONTROLLER 10 Install a red wire from the power supply V terminal to DVR RGB 60 VDC red terminal and a bla...

Page 7: ...soft strip black wire s 24 Connect the red wire into DVR RBG 60 Group 1 red terminal Connect the other end to RGB soft strip red wire s 25 Connect the green wire into DVR RBG 60 Group 2 green termina...