"N" White
"L" Black
" " GREEN
White +
Black -
SEL
V
10-24 V=
1-10V=
<0.6 mA
+
-
+
-
OUTPUTS TO LED MODULES
IN
DIM MODULE
POWER SUPPLY
"N" White
"L" Black
" " GREEN
White +
Black -
SEL
V
10-24 V=
1-10V=
<0.6 mA
+
-
+
-
OUTPUTS TO LED MODULES
IN
DIM MODULE
POWER SUPPLY
4
SEL
V
10-24 V=
1-10V=
<0.6 mA
+
-
+
-
OUTPUTS TO LED MODULES
IN
3
DIM MODULE
G
ELECTRICAL BOX
3
LIGHTOLIER:
ZP600FAM120
CONTROLLER
5
4
CONDUIT
3
POWER SUPPLY
3:
Install the conduits from the dimming controller, main panel
(line voltage), and soft strip to the power supply case.
4:
Run proper wire size and color from the controller electrical
box to the power supply case.
5:
Connect the black, white, red, purple, and gray controller
wires respectively to black, white, red, purple, and gray wires
with a wire nut. The yellow controller wire is not used in this
procedure. Cap the yellow controller wire with a wire nut. For
three way switching, refer to the instructions provided with
the controller.
H
LINE
VOLTAGE
WIRES
LIGHTOLIER:
ZP600FAM120
CONTROLLER
6:
Run the line voltage power wires into power supply case.
7:
Connect the hot power wire to black controller wire with a
wire nut.
8:
Connect the neutral power wire to white controller wire
and the white power supply wire marked "N" with a wire
nut.
9:
Connect the red controller wire to black power supply wire
marked "L" with a wire nut.
10:
Make sure the green transformer wire is grounded in
accordance with local electrical codes.
12
I
11
11:
Connect the gray controller wire to "-" terminal of "1-10V"
dim module.
12:
Connect the purple controller wire to "+" terminal of
"1-10V" dim module.
8
7
9
13:
Connect the white power supply wire marked "+" to "+"
terminal of "12-24V" dim module.
14:
Connect the black power supply wire marked "-" to "-"
terminal of "12-24V" dim module.
6
"N" White
"L" Black
" " GREEN
White +
Black -
J
13
14