Edge-Core AS4630-54PE Quick Start Manual Download Page 3

Quick Start Guide

–  3  –

Make Network Connections

(Optional) Make Stack Connections

Note:

 For information on initial switch configuration, refer to 

the Cumulus website for all system configuration documents.

https://docs.cumulusnetworks.com/

1. Edgecore Cumulus Linux software option

To make basic switch configuration changes, connect a PC to
the switch's RJ-45 console port using the included console cable.

2. Configure the PC’s serial port 

115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no 
flow control. Log in to the Linux interface using the default settings: 
User “cumulus” with password “CumulusLinux!”.

5

1. RJ-45 ports

Connect 100-ohm Category 5, 5e or better twisted-pair cable.

2. SFP+/SFP28 slots

First install SFP+/SFP28 transceivers and then connect fiber optic 
cabling to the transceiver ports.

6

1. Connect the top device

Plug one end of a DAC cable in the bottom QSFP28 port of the top 
unit.

2. Connect the next device

Plug the other end of the DAC cable into the top QSFP28 port of the 
next unit.

3. Repeat

Repeat for each unit in the stack.

4. (Optional) Connect the top and bottom devices 

Plug one end of a DAC cable into the bottom QSFP28 port on the 
bottom unit and the other end into the top QSFP28 port on the top unit.

5. Reboot

Reboot each switch in the stack to start the stack operations.

Note:

 

Stacking support is dependent on the switch software. 

For stacking support information, refer to the NOS software 
documentation.

Hardware Specifications

Switch Chassis

Size (WxDxH)

438 x 442 x 43.7 mm (17.24 x 17.40 x 1.72 in)

Weight

7.67 kg (16.91 lb), with two installed PSUs

Temperature

Operating: 0° C to 45° C (32° F to 113° F)
Storage: -40° C to 70° C (-40° F to 158° F)

Humidity

Operating: 5% to 90% (non-condensing)

Power 
Consumption

1800 Watts max.

System Input Power Rating

AC Input

100-120 Vac, 50-60 Hz, 12 A max.
200-240 Vac, 50-60 Hz, 7.5 A max.

Regulatory Compliances

Emissions

EN 55032:2015+AC:2016, Class A 
EN 61000-3-2:2014, Class A
EN 61000-3-3:2013
FCC Class A
VCCI Class A
CCC GB 9254-2008, Class A
BSMI Class A, CNS 13438

Immunity

EN 55024:2010+A1:2015
EN 55035:2017
IEC 61000-4-2/3/4/5/6/8/11

Safety

UL (UL 62368-1 & CSA C22.2 No. 62368-1)
CB (IEC/EN 60950-1, IEC/EN 62368-1)
CCC GB4943.1-2011
BSMI, CNS 14336-1

Taiwan RoHS

CNS 15663

Summary of Contents for AS4630-54PE

Page 1: ...Green stacking ports active FAN LED Green OK Amber fault PoE LED Green OK Amber High PoE load RJ 45 Port LEDs Green link Amber link with PoE Blinking activity SFP28 Port LEDs White 25G Green 10G Blink...

Page 2: ...the Rear Post Brackets Use the included screws to lock the position of the rear post brackets Note For switches with ONIE software pre loaded refer to the network operating system NOS installer and NO...

Page 3: ...peat Repeat for each unit in the stack 4 Optional Connect the top and bottom devices Plug one end of a DAC cable into the bottom QSFP28 port on the bottom unit and the other end into the top QSFP28 po...

Page 4: ...1 1x USB 2 1x 3 1x 4 LED 5 48x RJ45 1G PoE 6 4x SFP28 25G 7 2x QSFP28 40G 100G 8 3x 9 2 x AC PSU 4 8 1 9 7 2 6 3 5 STK M S LED PRI LED PSU LED STK LED LED OK PoE LED PoE RJ 45 LED PoE SFP28 LED 25G 1...

Page 5: ...arantie PSU Attention Le appareil comprend des modules d alimentation et de modules de ventilation install s dans son ch ssis Assurez vous que tous les modules install s ont une direction d air adapt...

Page 6: ...67 kg 16 91 lb PSU 0 C 45 C 32 F 113 F 40 C 70 C 40 F 158 F 5 90 1800 AC 100 120 Vac 50 60 Hz 12 A 200 240 Vac 50 60 Hz 7 5 A EN 55032 2015 AC 2016 Class A EN 61000 3 2 2014 Class A EN 61000 3 3 2013...

Page 7: ...E 1 1x USB 2 1x 3 1x 4 LED 5 48x RJ45 1G PoE 6 4x SFP28 25G 7 2x QSFP28 40G 100G 8 3x 9 2x PSU 4 8 1 9 7 2 6 3 5 STK M S LED PRI LED PSU LED STK LED LED PoE LED PoE RJ 45 LED PoE SFP28 LED 25G 10G QSF...

Page 8: ...par la garantie PSU Attention Le appareil comprend des modules d alimentation et de modules de ventilation install s dans son ch ssis Assurez vous que tous les modules install s ont une direction d ai...

Page 9: ...kg 16 91 lb PSU 0 C 45 C 32 F 113 F 40 C 70 C 40 F 158 F 5 90 1800 Watts max 100 120 Vac 50 60 Hz 12 A max 200 240 Vac 50 60 Hz 7 5 A max EN 55032 2015 AC 2016 Class A EN 61000 3 2 2014 Class A EN 61...