If the absence mode cannot be used it could be necessary to drain the water heater if the device is switched
off. Proceed as follows:
1. Advice to the user.
The device has to be disconnected from mains before opening the cover.
Maintenance
Warranty
Switch off power supply.
Open a hot water tap.
Close the cold water inlet.
Open the drain valve on the
security group.
❶
❸
❷
❹
In order to maintain the performances of your water heater, we advice to service it regularly.
2. Service.
By the USER :
What
When
How
Security group
1 to 2 times per month
Operate the safety valve.
Check that water evacuation is ok.
General
1 time per month
Check external shape of your device : no Error code
displayed, no leakage on the connections...
By the INSTALLER :
What
When
How
Ducts
1 per year
Check if the device is ducted.
Check if the ducts are well positioned and not
deformed.
Condensates evacuation
1 per year
Check the cleanness of the condensates evacuation
tube.
Electric connections
1 per year
Check that any internal and external cable connections
are not loose and that all connectors are plugged in.
Electric backup
1 per year
Check the correct function of the electric backup by
measuring the power.
Scaling
Every 2 years
If the supply water is hard clean the deposited scale.
What
When
How
Thermal exchange of the
heat pump
Every 2 years
Check the correct working of the heat pump.
Components of the heat
pump
Every 2 years
Check the ventilator operation on it’s 2 speeds and the
hot gas valve.
Evaporator
Every 2 years
Clean the evaporator with a nylon brush and products
neither scratching nor corrosive.
Refrigerant
Every 5 years
Check the refrigerant quantity.