Should you find any damage as a result of transit, please contact dealer immediately.
Installation
1.
Remove the appliance from the packaging an
2
d the protective film from all surfaces.
2.
Avoid positioning the appliance in direct sunlight or damp areas.
3.
Insert the slide-out shelf/shelves at the desired levels and place the smaller shelf/shelves on the floor
of the appliance.
4.
If necessary, adjust the screw feet of the appliance to make it level.
Operation
Control Panel
The control panel is located below the doors on the front of the
appliance.
Turn On
1.
Close the door of the appliance.
2.
Connect the appliance to a mains power supply..
To Change the Operating Temperature
The default operating temper
To change the operating temperature;
Press and Hold the button for 2 seconds, the “°C” will start to flash.
3. Press the button to store the temperature.
ature is 2 °C. To display the operating temperature (set point), press and
immediately release the
button.
Note: If the unit has not been stored or moved in an upright position, let it stand upright
for approximately 12 hours before operation. If in doubt allow to stand.
Note: Before using the appliance for the first time, clean the shelves and interior with
soapy water.
Note: The Cooling Light is illuminated when the appliance is chilling the interior cabinet.
Defrost Light Cooling Light
2.
1.
Press the
or
buttons to change the temperature.
Manual Defrost
The cooler feature an automatic defrost. However, should the appliance require an additional defrost
period press and hold the
button for 2 seconds.
Automatic defrost cycles are every 6 hours and last 20 minutes (factory defaults).
Note: If a manual defrost is started this resets the automatic defrost timer. During
defrost periods the Defrost light is illuminated.