   Print Date 31/08/11                                      Page 16 of 22                                    E2136-00MA-02 

2.3.2 Output Power Level and Frequency Adjustment 
 
If  the  Amplifier  is  not  supplied  with  preset  output  power  levels  and  frequency,  its  front  panel  SET 
POWER control and the Exciter/Drive(s)’ power output and frequency will need to be set. The manuals 
for the type of Exciter/Drive(s) supplied or in use must be consulted for information on how the settings 
required of them are actually made. 
 
The procedure is as follows : 
 

1)  Ensure the Amplifier has been  installed as detailed in sections 2.1 and 2.2. Check pin 11  of 

the  Status  Connector  SK02  is  not  grounded  (i.e.  is  set  for  internal  power  level  control  -  see 
section 2.2.2). 

 
2)  Break the rear panel Interlock connection at SK02, pins 20-21. 

 

3)  Apply  power  to  the  Amplifier  (i.e.  ensure  the  supply  distribution  16A  MCB  is  on,  the  supply 

lead  is  connected  and,  on  E2137-05,  06,  07  and  08  variants,  the  rear  panel  supply  switch 
SW01 is on ‘I’ ) 

 

4)  Ensure  all  the  displays  are  illuminated  (else  follow  fuse  checking  procedure  as  detailed  in 

section 2.3.1 (fault finding may be required if this occurs). Check Exciter/Drive(s) are operating 
and use the Amplifier’s front panel push button switch to select the ‘Fwd Power’ display. 

 

5)  Set  the  Exciter/Drive(s)  power  output  to  minimum  (which  must  be  less  than  13W)  and 

frequency to that required. 

 

6)  Set  the  Amplifier’s  front  panel  SET  POWER  twelve  turn  control  to  fully  anti-clockwise  (i.e. 

minimum power setting). 

 
7)  Reconnect the rear panel Interlock connection at SK02, pins 20-21. 

 

8)  Slowly adjust the Amplifier’s front panel SET POWER twelve turn control to fully clockwise (i.e. 

maximum power setting) checking for a gradual rise in output power. 

 

9)  Adjust  the  Exciter/Drive(s)  output  power  so  that  500W  is  just  obtained.  To  ensure  complete 

accuracy, an external calibrated  power meter should  be used to measure this output power. 
Increase the input level by a further 1dB (approximately 20%). In no case however must the 
input power exceed 13W 

 

10) With  the  Exciter/Drive  power  set  as  described,  turn  the  SET  POWER  control  anti-clockwise 

until the measured output power falls back to 500W (or less if required).

 

 

 

11) Check that the output power displayed on the front panel display. This reading will not be as 

accurate as the external calibrated power meter but should be within about 

±

0.25dB (approx. 

25W).  

 

12) Use the Amplifier’s front panel push button switch to select the ‘Rev Power’ display and check 

for reverse power less than about 15W 

 
 
The  Amplifier  will  now  be  ready  for  operation  with  audio  and  or  data  sources  applied  to  the 
Exciter/Drive(s).  The  manuals  for  the  type  of  Exciter/Drive(s)  supplied  or  in  use  must  be  again 
consulted for information on how such sources are applied and controlled. 
 
The  RF  Monitor  connector  at  the  rear  of  the  unit  can  be  used  to  check  the  close-in  spectrum  of  the 
Amplifier  output  signal.  Note  that  any  harmonic  levels  shown  will  not  necessarily  indicate  those 
present at the Amplifier output. Any test equipment should not however normally be left connected. 
 
 

Summary of Contents for xa500 series

Page 1: ...00 Series Low Power FM Amplifiers Installation and Operation Issue 2 E2136 00MA 02 August 2011 Eddystone Broadcast Ltd 26 Arden Rd Arden Forest Industrial Estate Alcester Warwickshire B49 6EP England...

Page 2: ...Print Date 31 08 11 Page 2 of 22 E2136 00MA 02 Intentional blank page...

Page 3: ...2 1 2 Rack Mounting Page 12 2 2 EXTERNAL CONECTIONS Page 12 2 2 1 Mains Supply Connector Page 12 2 2 2 Status Connector Page 13 2 2 3 RF Output Antenna Connector Page 14 2 2 4 RF Input Connector Page...

Page 4: ...Print Date 31 08 11 Page 4 of 22 E2136 00MA 02 Bound at Rear XA500 Front and Rear Views E2136 00GA XA500 Block Diagram E2136 00BK XA500 Interconnections Circuit Diagram E2136 00CT...

Page 5: ...ber of modules described as follows 1 1 1 7 inc Front and rear views a block diagram and a circuit diagram showing these modules are bound at the rear of this manual E2136 00GA E2136 00BK and E2136 00...

Page 6: ...processor operation and sets an additional red green CPU LED accordingly on the Display Board Equivalent information about levels and status is also fed to the Interface Board see section 1 1 6 and wh...

Page 7: ...rd 1 2 VARIANTS AND OPTIONS The variants indicted by number suffixes are as follows E2136 01 Basic XA500 500W Amplifier fitted with 7 8 in RF Output connector single PSU E2136 02 Basic XA500 500W Ampl...

Page 8: ...to 500W including open and short circuits does not cause any damage to the Amplifier Output Reverse Intermodulation Reverse intermodulation products will be better than or equal to 10dB relative to t...

Page 9: ...temperature than the ambient Altitude operating Up to 3000 metres a s l Mechanical Width 483mm 19 in Height 133mm 3U Depth 570mm intrusion into rack exc 7 8 in RF output connector Weight Approx 22kg...

Page 10: ...Print Date 31 08 11 Page 10 of 22 E2136 00MA 02 Intentional blank page...

Page 11: ...th as req d 3 core 2 5mm 2 per core insulated cable Mains supply lead 1 16A C rated 2 pole miniature circuit breaker MCB Fitted at mains supply distribution point to protect supply lead and mains inpu...

Page 12: ...supply is in the order of 9A at 110V to 4A at 260V at 500W RF output Note that certain variants E2136 05 06 07 and 08 have a rear panel on off switch in line with this connector see section 1 2 CAUTI...

Page 13: ...Interlock input ground to de mute Pin 22 Chassis Ground for External Power Control Voltage Input Pin 23 Ext Power Control Voltage Input 0V to 5V DC for min to max power 10k Pin 24 Interlock status rel...

Page 14: ...entre rear of the unit 2 2 5 RF Output Monitor Connector This is a 50 BNC coaxial socket SK04 at the centre rear of the unit This provides a sample of the Amplifier s forward output power into a 50 lo...

Page 15: ...the mains supply to the Amplifier is interrupted 0 75A Hold RXEF 075 Resettable Fuse For protection of the 50V dc output on the rear panel Status connector SK02 If this fuse goes high impedance any ex...

Page 16: ...e i e minimum power setting 7 Reconnect the rear panel Interlock connection at SK02 pins 20 21 8 Slowly adjust the Amplifier s front panel SET POWER twelve turn control to fully clockwise i e maximum...

Page 17: ...outputs any serial data via the COM port or RJ45 connector unless requested to by that unit The remote control unit always sends a sequence of three bytes waiting for each byte to be echoed correctly...

Page 18: ...ormal 4F O Stat_Low Status low 4C L Stat_High Status high 48 H Fail Status fail 46 F Amp_Muted Amplifier Muted 4D M Amp_Start Amplifier Unmuted 53 S Int_Sel Status Internally Selected 49 I Ext_Sel Sta...

Page 19: ...inc or X Op_Data15 Output Amplifier Type 1000W 500W 150W 300W or X Op_Data16 Output data 8 bit EOR checksum of 2 15 inc only Reverted Amplifier Data Block 15 extra bytes reverted in response to Y seq...

Page 20: ...Print Date 31 08 11 Page 20 of 22 E2136 00MA 02 Intentional blank page...

Page 21: ...vel in Watts and relating status Temp displays level in Deg C and relating status Current displays level in Amps and relating status SET POWER Preset Potentiometer twelve turns To set output power clo...

Page 22: ...22 E2136 00MA 02 3 1 2 E2322 Power Supply Units Marked Type Function DC LED Display Green indicates dc output 75 85 of its rated value AC LED Display Green indicates ac input 78 86Vrms CAUTION see not...

Reviews: