SECTION TWO : INSTALLATION
! CAUTION !
These Amplifiers operate at
high RF power levels, internal supply energy levels and mains
supply current levels
. They also incorporate devices containing
toxic BeO
. Before commencing
installation, it is recommended that the complete INSTALLATION section is read and understood.
The
instructions should then be strictly followed, by suitably qualified personnel, otherwise sub-
standard or even dangerous operation may result.
2.1 : PHYSICAL DIMENSIONS AND FITTING
2.1.1 Installation Accessories
Various installation accessories may be supplied as required. A list of these (including spare fuses) is
given below. Actual requirements depend on the configuration of the equipment supplied (e.g. with or
without Exciter/Drive(s), separate to or already fitted into a 19 inch rack, whether or not leads are
supplied ready made etc.). Note that extra, unlisted parts may be required for connections to any
Exciter/Drive(s) that are supplied (see manuals supplied with them).
Typical
Quantity
Description
Function
1
16A IEC mains connector.
For connection to lead from mains supply
distribution point.
Length
as req’d
3 core, 2.5mm
2
per core, insulated
cable.
Mains supply lead.
1
16A ‘C’ rated 2 pole miniature circuit
breaker (MCB).
Fitted at mains supply distribution point to
protect supply lead and mains input components
in the Amplifier.
1
7-16 RF coaxial free plug
(E2136-02, 04, 06 and 08)
For connection to lead from Antenna or RF
output load.
1
7/8 in coaxial connector/bullet
(E2136-01, 03, 05 and 07)
For connection to lead from Antenna or RF
output load.
Length
as req’d
Low loss RF coaxial cable, rated in
excess of Amplifier output power at
maximum ambient temperature.
RF output lead.
1
N type RF coaxial free plug.
For connection to lead from Exciter/Drive
Length
as req’d
Low loss RF coaxial cable, rated in
excess of Exciter/Drive output power
at maximum ambient temperature.
RF input lead.
1
25 Way D plug c/w cover.
For connection to leads from control/monitor
ancillary equipment.
Length
as req’d
Multi-core screened cable (number of
cores as required).
Control/monitor leads.
Length
as req’d
Heavy gauge grounding wire/strap.
For safety earth lead.
4
Screws c/w plastic cup washers and
rack caged nuts.
For fixing unit into19 inch rack.
2
Side support ‘L’ brackets c/w fixing
screws and washers.
For extra support to carry the Amplifier’s weight
in the rack.
2
16A (T) HBC 5x32mm (¼ x1¼ in)
Fuses
For protection of internal dc supply leads to
individual internal amplifier ‘pallets’..