Print Date 12/05/15 Page 21 of 32 S7600-00MA-08
The preset control (marked ‘REV TRIP’) is at the rear left hand side of the printed circuit board. Care
must be taken that none of the other four preset controls on the board are altered. Adjust the control
anti-clockwise until the output power reaches a maximum.
Note that if this preset control is ever advanced too far clockwise, this may cause a decrease in output
power with less than 13, 25 or 50W reverse power, i.e. with a relatively good antenna system and with
the E2025 REV led still green.
2.3.4 Serial Remote Control Baud Rate Setting
The operating Baud rate and be viewed and changed if required, by pressing [MODE] on the E2023
Transmitter Control Unit continuously for about 3 seconds. The screen will then change to show the
present rate and the four 'soft' keys below can be used to select 2400, 4800, 9600 or 19200 Baud.
The screen will time out in about 3 seconds after entry or after the last press of one of the four soft
keys. Timeout is 'counted' down on the display. The Baud rate is held in non-volatile RAM and is error
checked at power-on-reset, defaulting to 9600 if any Baud rate store error found.