Print Date 12/05/15 Page 12 of 32 S7600-00MA-08
Typical
Quantity
Description
Function
Length
as req’d
Low loss 50
Ω
RF coaxial cable, rated
in excess of Exciter/Drive output
power at maximum ambient
temperature.
RF input and dummy load leads.
1
Coaxial, 87.5 – 108MHz, 50
Ω
load
with suitable free connector, rated in
excess of Exciter/Drive output power
at maximum ambient temperature.
Exciter/Drives’ dummy load.
1
2 Way, 10A, 5.08mm pitch screw
terminal block (c/w wire shorting link).
(e.g. Weidmuller BL5.08/2)
External safety interlock connector (wire shorting
link is removed when connector is wired to
external safety circuits).
1 - 2
9 Way D plugs c/w covers.
For connection to leads from control/monitor
inputs of Exciter/Drive(s).
1 - 2
9 Way D sockets c/w covers.
For connection to parallel and serial RS232
remote control/monitor links.
1
15 Way D plug c/w cover.
For connection to additional control/monitor
input links.
Length
as req’d
Multi-core screened cable (number of
cores as required).
Control/monitor leads.
Length
as req’d
Heavy gauge grounding wire/strap.
For safety earth lead.
1-2
IEC 6A free plug to free socket mains
leads (1 metre, 3 core each
0.75mm
2
, EPR insulated, HOFR
sheathed for high temperatures).
For fused and switched mains supply
connections to Exciter/Drive(s).
8
Screws c/w plastic cup washers and
rack caged nuts.
For fixing S76005, S7601 or S7602 into 19 inch
rack.
2
Side support ‘L’ brackets c/w fixing
screws and washers.
For extra support to carry the Transmitter’s
weight in the rack.
3-9
500mA (F) Fuses (for smd holders,
‘Littelfuse’ R451.500)
For protection of control circuits within E2021
Amplifiers and E2025 Combiner Unit.
2-8
16A (T) HBC 5x32mm (¼ x1¼ in)
Fuses
For protection of internal dc supply leads to and
high current circuitry within E2021 Amplifiers.
4
6.3A (T) HBC 5x20mm Fuses
For protection of internal low current dc supply
leads and of mains supply leads and circuitry
intended for connection to Exciter/Drives(s).
2.1.2 Rack Mounting
If the Transmitter is not supplied ready mounted in a 19 inch rack, this will be required to be done at
time of installation.
! CAUTION !
The S76005, S7601 and S7602 (i.e. the assembly carrying the Amplifiers, Power Supplies, Controller,
Splitter/Drive Changeover and Combiner) are
heavy
. Before installation in a rack, the Amplifier
Modules and Power Supplies should be removed to reduce the overall weight and ease the process.
These units are removed from the front of the Transmitter, taking care to release the mechanical
securing locks first. The Fan Assembly may also be opened, unplugged and then removed from the
rear of the Transmitter.
The 19 inch rack should be of standard 600mm depth and at least 12U height (for the S76005 or
S7601) or 14U (for the S7602). Additional height will be required if Exciter/Drive(s) are to be fitted into
the same rack (recommended). These should be fitted below the actual Transmitter section for ease of
inter-wiring. Additional bottom support ‘L’ brackets are also be required at each side, below the
Transmitter, to help carry its weight. The Transmitter is then fixed to the front of the racking using eight
screws, plastic cup washers and caged nuts. The Amplifier modules, Power Supplies and Fan
Assembly can then be refitted and external connections made.