background image

The consumables are classified as:

SMALL:

 the spark fountain height 1.0-3.5m (error 0.5m), and the spot is rarely dropped,use for 

indoor. 

LARGE: 

the spark fountain height 2.0-5.0m (error 0.5m), and the sprayed spot has dropped 

ground,use for outdoor.

Consumables choice:

 Consumables are the customized formula for the test of our 

machines.  Please  select  our  consumables  to  avoid  affecting  the  effect  of  the  machine;  (No 

warranty service is provided for machines damage caused by consumables not from our 
company).

1

2

Consumables

Remark: The detail channel instruction, please refer to attached channel operation; if need use 

console do special effects, then please do programme by yourself.

2nd channel do

fountain (adjust the

fountain height from

up to down)

Push the second channel do fountain.

3

1

2

3

4

5

6

10

8

6

4

2

0

10

8

6

4

2

0

10

8

6

4

2

0

1st channel down a

little bit clean powder

(between 221-239)

End of event -- Clean powder (cleaning operation refer to point 7)

4

1

2

3

4

5

6

10

8

6

4

2

0

10

8

6

4

2

0

10

8

6

4

2

0

Summary of Contents for Pro EDDY-HW-01

Page 1: ...MODEL EDDY HW 01 EDDYLIGHT PRO COOL SPARKLER MACHINE USER MANUAL...

Page 2: ...ription 3 DMX address code adjustment PackageContents DMXInstruction 8 8 8 DMX ADD HEAT Means increasing DMX address code long press helps increase fast Means decreasing DMX address code long press he...

Page 3: ...e is ready to work DMX Blue light Flashing shows that DMX signal is connected otherwise no signal FAULT Yellow light The light is on with any malfunction HEAT Red light When the machine is heating sig...

Page 4: ...untain e ects the fountain time of each machine is 1 3 seconds can be adjusted by short press before do fountain L R A From left to right each machine do fountain on sequence LR M A From left right si...

Page 5: ...e Remote controller Please ensure su cient consumables before use After added consumables Cover the rubber plug don t add to wrong fountain hole OperationInstruction The hole add consumables Power STO...

Page 6: ...n indicator light always in lighting then can do fountain the display will show heating temperature Press special e ects A or B buttons will have related special e ects End of event Press CLE do clean...

Page 7: ...No warranty service is provided for machines damage caused by consumables not from our company 1 2 Consumables Remark The detail channel instruction please refer to attached channel operation if need...

Page 8: ...entsused avoidbestuckbyinside powder for next use The series of products designed two automatic modes of cleaning remaining consumables Operation step When the machine still in the preparatory state a...

Page 9: ...ng failure 1 Check if the heat dissipation plate is normal 2 Replace the heat dissipation plate or heating board E03 1 Check the cooling fan 2 stop heating and operating restart after 10 minutes E02 H...

Page 10: ...hine operation Warning Dangerous voltages are present in this machine when electrical power is applied There is a danger of injury from electric shock Under no circumstances are you to attempt to open...

Page 11: ...tely turn o the power The heat dissipating fan should take out the internal air when the power is on Otherwise the internal heat is quickly transmitted to the surface of housing Please place the equip...

Page 12: ...5 12 Power Switch DMX Port 6 13 Power Port Foldable Handle 7 14 Factory Code Access Hole 19 Cleaning hole Product Parameters Working Height Fountain Direction Working Temperature Heating Power Fuse 1...

Page 13: ...rn o F6 136 159 Fountain 6 11 220 Emergency stop Add E57 F1 16 39 Fountain 1 F7 160 183 Fountain 7 221 239 Clear Powder CLE F2 40 63 Fountain 2 F8 184 207 Fountain 8 240 255 Pre heat turn on 0 500 F3...

Page 14: ......

Reviews: