Vehicle and Tether Connection
It is important that the tether be properly connected to the vehicle
– otherwise damage or loss of the system
may result.
1.
Connect the vehicle end of tether to the back of the vertical crawler. Visually line up the key in the
connector before mating. Fully screw down and hand-tighten the locking collar. Do not use tools
because the connector can then be easily be overtightened.
2.
Secure both lanyards to the Kellems grip using a quick link as illustrated below. Adjust the Kellems
grip position to maintain a small amount of slack tether regardless the direction the tether is pulled.
3.
Verify all device whips from the harness block to their respective components are securely con-
nected, and the whips are free from damage.
4.
Ensure all unused connectors are capped with dummy plugs to insulate and protect their electrical
contacts.