Tables Configuration
For every map, it is important to define, which input signals will be modified and which signals will be used as
Load
for the main map as well as for the corrections.
To enter Tables configurations, choose
Setup tables
from the menu
Setup…
The
modified signal for the
Fuel Table
can be chosen among
Analog#1-Analog#4, Frequency
and
Zero
.
Depending on the kind of a sensor (analog, frequency), a proper input can be chosen.
Zero
means that the value of
a modified input signal will be 0. This option is used for the MAF to MAP conversion.
.
For the Load, it is possible to choose all analog inputs and frequency input. For the correction maps, apart from the
choices mentioned above, there is also a Disable option, which switches the correction off.