5.2 Channels
•
Voltage in - voltage on battery side
•
Voltage out - voltage on car side
•
Current load - current flowing through the relay. Positive values: battery to car, negative: car to
battery (charging). Current load is not intended for precise current measurements but for general
information on device load and charging. Have in mind the measurement accuracy when
interpreting results.
•
Temperature – device internal temperature
•
Flags:
FLAG
SET condition
RESET condition
Overvoltage
Battery voltage > 19V
Battery voltage <= 19V
Undervoltage
Battery voltage < battery saver threshold
voltage
Battery voltage >= battery saver
threshold voltage
Overheat
Temperature > 80°C
Temperature <= 80°C
Overheat kill
Temperature > 90°C
Device reset
Overcurrent kill
Current > current limit
Device reset
Emergency kill
Emergency switch activated
Device reset
Powersave kill
Power save switch activated
Power save switch deactivated
CAN kill
CAN kill message received
Device reset
UVLO kill
Battery voltage < 6V
Device reset
Load dump occurred
Alternator is still charging when isolator
disconnects
Device reset
Battery saver kill
Battery saver function turned off power
Device reset
Overvoltage kill
Voltage exceeded device specification for
too long
Device reset
•
Device state - refer to Operation principles
•
Kill countdown - time remaining to go from POWER SAVE ENTRY PROC to POWER SAVE
or from EMERGENCY ENTRY PROC to OFF
•
Heartbeat - counter indicating that device is running, incremented with every CAN message
sent