Charging Stages
Stage 1 - Desulphation
Removes sulphation before commencing charging.
Stage 2 - Soft Start
Gentle initial charge for increased battery lifespan.
Stage 3 - Bulk
Main charge up to 80 % of capacity.
Stage 4 - Absorption
Gentle charge to 100 % of capacity.
Stage 5 - Analyse
Battery is checked for self discharge.
Stage 6 - Recondition
Reconditioning of deeply discharged battery.
Stage 7 - Float
Keeps the battery charged at 100 % of capacity without
overcharging or damaging it.
Stage 8 - Pulse
Keeps battery charged at 95 - 100 % of capacity.
The 8 stages are: