ECTIVE
®
POWER INVERTER – MI-/TMI-SERIES
]
28
Contin
uous
output
Model
MI/TMI
Input
voltage
recommended
battery cabel*
Battery
capacity**
2500 W
252
12 V
16 mm², 2 sets
≥
400 Ah
254
24 V
10 mm², 2 sets
≥
200 Ah
258
48 V
6 mm², 2 sets
≥
100 Ah
3000 W
302
12 V
16 mm², 2 sets
≥
480 Ah
304
24 V
10 mm², 2 sets
≥
240 Ah
308
48 V
6 mm², 2 sets
≥
120 Ah
* One set contains one positive and one negative wire .
** Recommended capacity of the batteries during permanent power .
ѥ
Warning!
Fire hazard!
If 2 sets of battery cables are recommended, both sets must also be installed . Failure
to do so can easily lead to overheating of the overloaded cables and connection points
and cause a dangerous cable fire .
⚠
Caution!
Please note the capacity!
An underrun of the recommended battery capacity can cause a loss of performance or
serious use restrictions as a result of voltage drops .
⚠
Caution!
Please respect a sufficient ventilation!
The inverter produces heat loss . The device is equipped with a thermal overload pro-
tection . An insufficient ventilation can affect the function of the inverter, because the
inverter can shut itself down for safety reasons .