23015-6-0408

Page 14

ALTERNATE ON/OFF SWITCH INSTALLATION

WIRING THE FIREPLACE
Note: Electrical wiring must be installed by a licensed electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF YOU ARE AB-

SENT FOR EXTENDED TIME PERIODS. THIS WILL PREVENT 

ACCIDENTAL FIREPLACE OPERATION.

Installation of Alternate Surround Panel ON/OFF Switch

An ON/OFF switch and wire assembly are provided. They are included 

in the instruction packet.

Do not cut wire or insulation on metal edges.

Note: Refer to surround panel installation section on page 15 for ad-

ditional information on attachment.
Contemporary Surrounds

1.  Find the coiled low voltage wire assembly and ON/OFF switch lo-

cated in the instruction packet.

2.  Attach the flag terminal ends to the “TH/TP” and “TH” terminals on 

the front terminal block of the gas valve.  

See Figure 13.

3.  Run the low voltage alternate switch wires up the back of the right 

or left surround panel. Then secure the wires with wire clips pro-

vided.  

See Figure 11.

Figure 11

Insert  ON/OFF  switch  into  side  panel  then  attach  wire  assembly 

from valve terminals.

4.  Remove the switch knockout on the side surround panel, then install 

the ON/OFF switch.

5.  Connect  the  low  voltage  wires  from  the  gas  valve  to  the  

ON/OFF switch.

6.  Attach the surround panel assembly to the insert. Place the surround 

panel assembly against the face of the insert and align the lower 

retaining tabs with the notches on the insert sides. Lift the surround 

panel assembly slightly until the bottom return flange (top panel) 

is positioned over the top flange on the insert. This secures the sur-

round panel assembly to the insert without screws.

Traditional Cast Iron Surrounds

1.  Find the coiled low voltage wire assembly and ON/OFF switch lo-

cated in the instruction packet.

2.  Attach the flag terminal ends to the “TH/TP” and “TH” terminals on 

the front terminal block of the gas valve.  

See Figure 13.

WIRING FROM

MILLIVOLT GAS

VALVE

ON/OFF

SWITCH

ASSEMBLY

Right Side Installation

Left Side Installation

ON/OFF

SWITCH

ASSEMBLY

Figure 12

Note: For right side leg installation, reverse switch position in 

bracket.

3.  Run the low voltage alternate switch wires up the back of the right 

or left cast surround leg. Then secure them with the wire clips pro-

vided. 

4.  Install the switch bracket with screws as shown in 

Figure 12

 to the 

back of the cast surround leg.

5.  Install  ON/OFF  switch,  and  connect  low-voltage  wires  from  gas 

valve.

6.  Attach  cast  surround  panel  assembly  to  the  insert.  Place  the  cast 

surround assembly against the face of the insert and align the lower 

retaining tabs with the notches on the insert sides. Lift the cast sur-

round assembly slightly until the bottom return flange (top panel) 

is positioned over the top flange on the insert. This secures the cast 

surround assembly to the insert  without screws.

Figure 13

Summary of Contents for DV25IN33L-1

Page 1: ...iance is not convertible for use with other gases unless a certi ed kit is used GAS FIRED Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store...

Page 2: ...10 12 Vertical Termination 13 Alternate ON OFF Switch Installation 14 Surround Panel Installation 15 Blower Accessory Information 16 Log Placement 17 Operating Instructions 18 Standing Pilot Lighting...

Page 3: ...t clean Vent cap is hot while replace is in operation Installation and repair should be done by a QUALIFIED SERVICE PERSON The appliance should be inspected before use and at least annually by a quali...

Page 4: ...perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wal...

Page 5: ...ng jurisdiction State of Massachusetts The installation must be made by a licensed plumber or gas tter in the Commonwealth of Massachusetts The installation must conform with local codes or in the abs...

Page 6: ...talling to an existing round replace chimney pipe DVVK3FV Vertical Vent Kit 25 Two pieces of 25 FlexVent Rectangle Cap Flashing connectors and clamps Recommended when installing to a square or rectang...

Page 7: ...28 14 1 2 11 1 8 25 1 4 12 3 4 17 18 5 16 27 6 3 4 9 20 25 5 8 40 DV33IN 22 3 4 31 16 14 1 8 28 1 4 14 1 4 18 3 4 21 5 16 30 8 1 4 10 1 2 21 1 2 28 5 8 43 DV35IN 24 3 4 34 16 16 1 8 31 1 4 14 1 4 21 3...

Page 8: ...10 1 3 4 23 11 Combustible Material No greeting cards stockings or ornamentation of any type should be placed on or attached to the replace The ow of heat can ignite combustibles Figure 4 8 MINIMUM CL...

Page 9: ...s results in pressures in excess of 1 2 psig 14 w c 3 5 kPa on the replace gas valve it will result in a hazardous condition Checking Manifold Pressures Both Propane and Natural gas valves have a buil...

Page 10: ...sting air circulation vents or grills NOTE Cutting of sheet metal parts of a replace in order to install the replace insert is prohibited WARNING Only the surround as supplied may be used to cover int...

Page 11: ...asonry chimney may need to be removed to allow installation of the exible vent pipe When installing into a zero clearance factory built wood burning replaces the use of the DVKI Round Vertical Termina...

Page 12: ...NT CONNECTION RETAINER SCREWS MAY BE INSTALLED THROUGH THE VENT CLAMPS TO ENSURE POSITIVE SECUREMENT OF VENTING SCREWS ADDED THROUGH VENT CLAMPS TO RETAIN VENTING TO COLLARS RECOMMENDED USE HIGH TEMP...

Page 13: ...ly dripping out at joints or seams Condensate can cause corrosion of caps pipe and ttings It may be caused by having excessive lateral runs or having exterior portions of the system exposed to cold we...

Page 14: ...ound panel assembly against the face of the insert and align the lower retaining tabs with the notches on the insert sides Lift the surround panel assembly slightly until the bottom return ange top pa...

Page 15: ...FINISHING THE FIREPLACE INSERT NEVER OBSTRUCT OR MODIFY THE AIR INLET OUTLET LOUVERS ON THE FIREPLACE IN SERT IN ANY MANNER NOTE INSTALL SURROUND PANELS SO THAT THE TOP PANEL RETURN FLANGE SLIDE S OV...

Page 16: ...nd BTU input level setting control by adjustment of the HI LO knob located on the gas valve Blower removal instructions Servicing or removal of the blower system must be performed by a quali ed servic...

Page 17: ...support Note DV25IN models incorporate two small tabs in the rear log support that keep the back log positioned correctly DV33IN models have one small tab in the rear log support to ensure the back lo...

Page 18: ...N position This time period allows the millivolts electrical current to build up to a suf cient level allowing the gas control to operate properly 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for sta...

Page 19: ...switch to desired setting FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a re or explosion may result causing property damage personal injury or loss of l...

Page 20: ...ptional Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8m or less length of 18 A W G minimum wire and connect it to the replace valve pigtails WARNIN...

Page 21: ...s from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt meter Take the reading atTH TP TPterminals...

Page 22: ...that no debris is interfering with the ow of air Inspect entire vent system for proper function Cleaning Logs Use a soft brush attachment on a vacuum cleaner to gently remove dust or soot deposits fr...

Page 23: ...what your dealer can furnish contact Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 Black Gold Finish Hammered Pewter Brushed Stainless Black Gold Finish Hammered Pewt...

Page 24: ...23015 6 0408 Page 24 INSERT PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 33 34 35 36 37 38 39 40 41 7 12 32 42 43 18 44 45 46 48 47 49...

Page 25: ...23a P286 P270 P244 ORIFICE MAIN BURNER NAT 23b P214 P210 P245 ORIFICE MAIN BURNER LP 24 23311 23017 23017 BURNER ASSEMBLY 25 22959 22959 22959 VALVE BRACKET 26 22739 22738 22738 TUBING ASSEMBLY 27 22...

Page 26: ...ne the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Fireplace Number Part Description Fir...

Page 27: ...23015 6 0408 Page 27 SERVICE NOTES...

Page 28: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: