R10 | R20 | R35 | R45 | R80 | R90 C/H performance data
Table 2
Model
R10_ | R20_ | R35_
R45_ | R80_ | R90_
Cooling
Sensible
Heat
Ratio
EER Heat Pump COP
Indoor Air
Flow
Fresh Air
Inlet Flow
Outdoor
Sound Level
Shipping
Weight
Btuh (kW)
Btuh (kW)
CFM (L/s)
CFM (L/s)
dBa
lbs (Kg)
R_ _C 09
9,200 (2.7)
0.79
9.5
N/A
N/A
400 (189)
35 (17)
75
140 (64)
R_ _H 09
9,200 (2.7)
0.79
9.5
8,500 (2.5)
2.90
400 (189)
R_ _C 12
12,000 (3.5)
0.66
8.8
N/A
N/A
400 (189)
50 (24)
69
140 (64)
R_ _H 12
12,000 (3.5)
0.66
8.8
11,700 (3.4) 2.60
400 (189)
R_ _C 15
14,700 (4.3)
0.69
8.3
N/A
N/A
425 (200)
60 (28)
70
140 (64)
R_ _H 15
14,700 (4.3)
0.69
8.3
14,000 (4.1) 2.52
425 (200)
R_ _C 18
16,500 (4.8)
0.67
8.3
N/A
N/A
425 (200)
95 (45)
69
140 (64)
R10 | R20 | R35 | R45 | R80 | R90 C/H hydronic heat * — performance 104-101 (single row coil)
Table 3
ºF
ºC
ºF
ºC
CFM m^3/min GPM
LPM
ºF
ºC
Btu/h
kW
ft H2O m H2O
ºF
ºC
ºF
ºC
450
12.7
2.9
11.1
180
82
14,300
4.2
2.8
0.8
170
77
10
6
400
11.3
2.8
10.4
180
82
13,500
4.0
2.5
0.8
170
77
10
6
450
12.7
1.7
6.4
140
60
8,400
2.5
1.1
0.3
130
54
10
6
400
11.3
1.6
6.1
140
60
7,900
2.3
1.0
0.3
130
54
10
6
450
12.7
3.0
11.4
180
82
14,400
4.2
2.9
0.9
170
77
10
5
400
11.3
3.0
11.4
180
82
13,600
4.0
2.9
0.9
171
77
9
5
450
12.7
3.0
11.4
140
60
9,000
2.6
3.1
0.9
134
57
6
3
400
11.3
3.0
11.4
140
60
8,600
2.5
3.1
0.9
134
57
6
3
450
12.7
2.0
7.6
180
82
13,700
4.0
1.4
0.4
166
74
14
8
400
11.3
2.0
7.6
180
82
13,000
3.8
1.4
0.4
167
75
13
7
450
12.7
2.0
7.6
140
60
8,600
2.5
1.5
0.5
131
55
9
5
400
11.3
2.0
7.6
140
60
8,200
2.4
1.5
0.5
132
55
8
5
450
12.7
1.0
3.8
180
82
12,100
3.5
0.4
0.1
155
68
25
14
400
11.3
1.0
3.8
180
82
11,500
3.4
0.4
0.1
156
69
24
13
450
12.7
1.0
3.8
140
60
7,500
2.2
0.4
0.1
125
52
15
9
400
11.3
1.0
3.8
140
60
7,200
2.1
0.4
0.1
125
52
15
8
450
12.7
4.3
16.1
180
82
20,800
6.1
7.0
2.1
170
77
10
6
400
11.3
4.0
15.1
180
82
19,400
5.7
6.2
1.9
170
77
10
6
450
12.7
2.5
9.3
140
60
12,100
3.5
2.8
0.8
130
54
10
6
400
11.3
2.3
8.7
140
60
11,300
3.3
2.5
0.7
130
54
10
6
450
12.7
3.0
11.4
180
82
19,900
5.8
3.7
1.1
166
75
14
8
400
11.3
3.0
11.4
180
82
18,800
5.5
3.7
1.1
167
75
13
7
450
12.7
3.0
11.4
140
60
12,500
3.7
4.0
1.2
132
55
9
5
400
11.3
3.0
11.4
140
60
11,800
3.5
4.0
1.2
132
56
8
4
450
12.7
2.0
7.6
180
82
18,700
5.5
1.8
0.5
161
72
19
11
400
11.3
2.0
7.6
180
82
17,700
5.2
1.8
0.5
162
72
18
10
450
12.7
2.0
7.6
140
60
11,700
3.4
1.9
0.6
128
53
12
7
400
11.3
2.0
7.6
140
60
11,100
3.3
1.9
0.6
129
54
11
6
450
12.7
1.0
3.8
180
82
15,800
4.6
0.5
0.2
148
64
32
18
400
11.3
1.0
3.8
180
82
15,100
4.4
0.5
0.2
149
65
31
17
450
12.7
1.0
3.8
140
60
9,800
2.9
0.6
0.2
120
49
20
11
400
11.3
1.0
3.8
140
60
9,400
2.8
0.6
0.2
121
49
19
11
R80
R90
Water Delta
Water Flow
Consult Factory For All Hydronic Coil Requests
Water Leaving
Hydronic Coil Code
Part Number
Model
104 000 101
Air Entering Flow
Rate
Water Entering
Capacity
Pressure Drop
56
13
R20
Air Entering Dry
Bulb
Air Entering
Wet Bulb
R10
R35
R45
104 000 130
70
21
21
70
56
13
NOTICE
Due to EMI’s ongoing development programs, design, specifications, and performance data is subject to change with-
out notice. Please consult the factory for further information. For the most current unit/system performance data,
please refer to our website, at www.ecrinternational.com, or Enviromaster International listing of certified products in
the ARI certified directory, at www.ahridirectory.org.
Tested/Rated
in Accordance with
ARI 310/380 and
UL Standard 484
Performance Data
Replacement Packaged Terminal Air-Conditioning / Heat Pump
• Installation, Operation, and Maintenance Manual •
P/N 240008034, Rev. D [7/29/2011]
35
Made in USA