![ECR International 18k Installation, Operation & Maintenance Manual Download Page 18](http://html1.mh-extra.com/html/ecr-international/18k/18k_installation-operation-and-maintenance-manual_2356177018.webp)
PN 615000208, Rev A [06/30/2017]
ECR International, Inc.
2201 Dwyer Avenue • Utica, New York 13501
Phone: 800.253.9364 • Web:
emiretroaire.com
Presents
Multi-Zone Programming Requirement
Follow the steps below to program
EACH
Air Handler
Control:
1.
Disconnect Power of outdoor unit and indoor unit.
2.
Wait one (1) minute. Resume power to both indoor
and outdoor units.
3.
Use remote to turn Indoor unit
ON
. With remote turn
Indoor unit
OFF TO STANDBY MODE
. Indoor unit
display will be blank.
4.
Remove batteries from Wireless Remote Controller.
5.
Press
ON/OFF
button and wait until Wireless Remote
Controller screen is blank.
Note
DO NOT POINT
Wireless Remote Controller at the
Indoor Unit for steps 6 and 7.
6.
Install batteries into Wireless Remote Controller.
7.
Immediately press and hold
MODE, FAN and TIMER-
ON
button for 3 seconds until Wireless Remote
Controller enters
ENGINEERING MODE
.
Iverter
Multi-Zone
Wireless Remote Controller Programming Instructions
Note
POINT REMOTE
at INDOOR UNIT for steps 8-12.
8.
Press
UP
button until Wireless Remote Controller
displays
F4
.
9.
Press
MODE
button, Wireless Remote Controller
displays
1
.
10.
Press
TIMER-ON
button, while
1
is still shown on
display. Wireless Remote Controller will show
F4
,
Indoor Unit will beep once and display
01
.
11.
Remove batteries. Push
ON/OFF
button screen will be
blank.
12.
Install batteries to exit
ENGINEERING MODE
.
Operate A/C and Heat cycles to test remote.