9. Sensor Calibration

CO2:There is an easy way to find the CO2 sensor is

drifted or not: put the sensor in outdoor open air locations,

away from any combustion exhausts, wait for 30 minutes,

you should see the CO2 reading is /-10. If it is

far from this reading, you can wait for some more time,

and test it during night to confirm. Once it is confirmed,

you can open the back housing, and use a clipper pin to

press the Calibrate button as below figure shows, leave it

for 30s, and the reading will be shifted back to 420ppm.

Figure 3

Summary of Contents for WH45

Page 1: ...4 3 Features 5 4 Sensor Set Up 7 5 Sensor Installation 10 6 Wi Fi Configure with Gateway 12 6 1 Pair with Gateway 12 6 2 Wi Fi Connection for the Gateway 13 7 View Online Data on the web page ecowitt net or WS View Plus Ecowitt App 13 8 Appendix 15 9 Sensor Calibration 18 10 Specification 20 11 Warranty Information 23 ...

Page 2: ...are il codice QR perleggi il manuale italiano e conservalo perReferenza futura Instruction manuals https www ecowitt com support download 97 Help Our product is continuously changing and improving particularly online services and associated applications To download the latest manual andadditional help please contact our technical support team support ecowitt com support eu ecowitt net EU UK ...

Page 3: ...ur purchasing of this integrated multifunct ion indoor air quality monitoring sensor It measures PM 2 5 PM10 CO2 Temperature Humidity To ensure the best product performance please read this manual and retain it for future reference ...

Page 4: ...missing Inside you should find the following QTY Item Description 1 Particle Detection Sensor PM2 5 PM10 CO2 Temperature Humidity 5 In 1 1 USB Cable 1 User Manual Table Package content If any component is missing from the package or broken please contact our Customer Service department to resolve the issue ...

Page 5: ...very 10 minutes when powered with batteries only USB power connection for indoor use only CO2 value calibration function available on the device PM2 5 value Calibration function available when paired with the WiFi Gateway GW1100 HP2551 HP3500 HP3501 Long wireless range up to 300 feet 100 meters in open areas When paired with a the WiFi Gateway GW1100 Wi Fi Gateway ...

Page 6: ...he Live Data page of the WS View Plus Ecowitt App Displays current CO2 concentration and 24H average CO2 concentration on the Live Data page of the WS View Plus Ecowitt App Displays temperature and humidity data where the sensor located Calibration function available for PM2 5 value When paired with a Weather Station Console HP2551 HP3500 HP3501 The PM2 5 PM10 and CO2 data automatically scrolls di...

Page 7: ...ote monitoring with smart phone laptop or computer by visiting the website Note On the 48 hour self test which takes place with maximum fan rotation and is therefore clearly perceptible You can set the commissioning start time by removing the batteries and the USB connection to a point in time where the necessary fan noise does not interfere 4 Sensor Set Up 1 Remove the battery door on the base of...

Page 8: ...ription 1 Red LED Indicator RF transmission 3 Battery Compartment Cover 2 AC Adapter USB Power Port 4 Battery Compartment 2 Insert two AA batteries and close the batterydoor Note The batteries not included are mainly for backup purpose ...

Page 9: ...luded Note After inserting the batteries or connecting AC power the sensor LED indicator will light for 3 seconds flash once after 20s and then flash once per 1 minute thereafter 10 minutes if only powered by batteries Each time it flashes the sensor is transmitting data ...

Page 10: ...lear of any obstructions and we recommend placement away from other electronic devices to prevent interference Do not place on a metal table to prevent RF signal loss Note This sensor is designed for indoor use only Wireless communication is susceptible to interferen ce distance walls and metal barriers We recomme n d the following best practices for trouble free wirele ss communication 1 Electro ...

Page 11: ...id intermittent communication 3 Line of Sight Rating This device is rated at 300feet line of sight no interference barriers or walls but typically you will get 100feet maximum under most real world installations which include passing through barriers or walls 4 Metal Barriers Radio frequency will not pass through metal barriers such as aluminum siding If you have metal siding align the remote and ...

Page 12: ...iFi Gateway GW1100 has been in operation and you have never had any WH45 sensor setup before just power up the sensor and the WiFi Gateway GW1100 will pick sensor data automatically If a WH45 sensor has been hooked on the WiFi Gateway GW1100 before and you have a new sensor to replace the old one just power off the old sensor and power on the new sensor open the APP WS View Plus Ecowitt App tap th...

Page 13: ...iFi Gateway GW1100 Wi Fi gateway Any question please contact the customer service 7 View Online Data on the web page ecowitt net or WS View Plus Ecowitt App When the Wi Fi configuration is done you can view the live data of your sensor on the web page ecowitt net or WS View Plus Ecowitt App ...

Page 14: ... doesn t support uploads to weather underground If you choose to upload the data to our weather server https www ecowitt net you can view the live data history graph and download the records on the website You can add a shortcut of the website on the home screen of your phone for quick access ...

Page 15: ...x AQI for the PM2 5 Concentration 24hr AQI Air Pollution Level PM2 5 Concentration ug m3 0 50 Good 0 0 12 0 51 100 Moderate 12 1 35 4 101 150 Poor 35 5 55 4 151 200 Unhealthy 55 5 150 4 201 300 Severe 150 5 250 4 300 Hazardous 250 5 ...

Page 16: ...indicated below 250 350 ppm background normal outdoor air level 350 1 000 ppm typical level found in occupied spaces with good air exchange AQI Air Pollution Level PM2 5 Concentration ug m3 0 50 Good 0 54 51 100 Moderate 55 154 101 150 Poor 155 254 151 200 Unhealthy 255 354 201 300 Severe 355 424 300 Hazardous 425 ...

Page 17: ...t nausea may also be present 5 000 ppm This indicates unusual air conditions where high levels of other gases also could be present Toxicity or oxygen deprivation could occur This is the permissible exposure limit for daily workplace exposures 40 000 ppm This level is immediately harmful due to oxygen deprivation Reference link https ohsonline com Articles 2016 04 01 Carbon Dioxide Detection and I...

Page 18: ...usts wait for 30 minutes you should see the CO2 reading is 420ppm 10 If it is far from this reading you can wait for some more time and test it during night to confirm Once it is confirmed you can open the back housing and use a clipper pin to press the Calibrate button as below figure shows leave it for 30s and the reading will be shifted back to 420ppm Figure 3 ...

Page 19: ...ibrate through the web page ecowitt net or WS View Plus Ecowitt App when paired with the WiFi Gateway GW1100 or on the console when pairedwith HP 2551 HP3500 HP3501 which saves the offset value on the gateway side before sending data to www ecowitt net server However if PM2 5 data is persistently low it can be that there is a spider net going inside the sensor So please clean the sensor from time ...

Page 20: ...Resolution PM 2 5 0 999ug m3 0 100ug m3 10ug m3 100 1000ug m3 10 1ug m3 PM 10 0 999ug m3 0 100ug m3 25ug m3 100 1000ug m3 25 1ug m3 CO2 0 40000ppm 400 10000ppm 30ppm 3 1ppm Temperature 40 C 60 C 40 F 140 F 1 C or 2 F 0 1 C or 0 1 F Humidity 1 99 5 1 ...

Page 21: ...te 10 minutes when only powered by batteries Power consumption Particle Detection Sensor AC power 5V 1A Not included 2 x AA 1 5V Batteries for back up Not included Note One set alkaline battery could only last for three days when sensor powered by battery only Note If you have a WH41 or WH43 PM2 5 sensor the reading of PM2 5 may be different due to different sensor type used ...

Page 22: ...ture and humidity reading may vary due to different environment When the sensor is placed at unventilated environment the temperature reading may be 2 degrees higher in worst case When the sensor is placed at ventilated environment the temperature and humidity reading may be lower than the actual reading ...

Page 23: ...original date of purchase is valid only on products purchased and only to the original purchaser of this product To receive warranty service the purchaser must contact us for problem determination and service procedures This limited warranty covers only actual defects within the product itself and does not cover the cost of installati on or removal from a fixed installation normal setup or adjustm...