INITIAL START
–UP
Carefully inspect your system before initial start
–up. Check that all plumbing and electrical
connections are not loose or have not come undone during shipment.
Direct the permeate water line to drain for this procedure.
1. Fully open the concentrate valve by turning it counter
–clockwise.
(#12, Figure 1, Page 11)
2. Fully close the concentrate recycle valve by turning it clockwise.
(#14, Figure 1, Page 11)
3. Plug the RO system in and adjust the concentrate (waste) valve and recycle valve to
the designed flow and pressure.
4. Inspect the system for leaks.
5. Allow the system to run 30 minutes to flush the preservative solution from the system.
6. After 30 minutes, shut down the system.
7. Re
–direct the permeate water back to the tank and then turn the system back on.
8. Record the readings daily for a week; after one week record the readings once a
week.
Summary of Contents for ELC-1500
Page 1: ...Membrane System User Manual ELC Series ELC 1500 w...
Page 2: ...ELC Series User Manual MKTF 506 A 2 03 18 This page intentionally left blank...
Page 11: ...ELC Series User Manual MKTF 506 A 11 03 18 SYSTEM IDENTIFICATION Figure 1...
Page 15: ...ELC Series User Manual MKTF 506 A 15 03 18 Figure 2...
Page 16: ...ELC Series User Manual MKTF 506 A 16 03 18 Figure 3...
Page 26: ...ELC Series User Manual MKTF 506 A 26 03 18 OPERATING LOG...
Page 30: ...ELC Series User Manual MKTF 506 A 30 03 18 ELC 750 FLOW DIAGRAM...
Page 31: ...ELC Series User Manual MKTF 506 A 31 03 18 ELC 1500 FLOW DIAGRAM...
Page 32: ...ELC Series User Manual MKTF 506 A 32 03 18 ELC SERIES ELECTRICAL SCHEMATIC...