5
Connecting the heater to the 230V electricity supply
WARNING: DO NOT TURN POWER ON IF THE HEATER IS EMPTY!
Note:
This should only be done by a qualified electrician.
With the electricity supply turned off and isolated, connect the live
wire (brown) to the live terminal (L) of the isolating switch. Connect
the neutral wire (blue) to the neutral terminal (N) of the isolating
switch. Connect the earth wire (green/yellow) into the earth terminal
(E) of the isolating switch. When all 3 wires have been terminated
to the 230V supply switch is it then safe to turn on the heater.
The heater will now begin to heat up and will take approx. 30 minutes
to reach uniform surface temperature.
Filling the heater with water
-
JT4B – Pour 330ml of water into the heater
-
JT6B – Pour 450ml of water into the heater
Fit and tighten the 4 valve locks into the sides of the heater. Fill the heater
with the correct amount of water and fit the 5th valve lock with bleed
valve to the top of the heater as shown below