JTB Electric Radiators Installation
and Operational Manual
JT4B and JT6B versions
JT
4B R
adiator
6B R
www.ecovolt.ie
Page 1: ...JTB Electric Radiators Installation and Operational Manual JT4B and JT6B versions JT4B Radiator JT6B Radiator www ecovolt ie...
Page 2: ...petent person All electrical work to be completed by a qualified electrician Please dispose the package properly Towel Rail Installation 1 Drill 2 Screwdriver s 3 Spirit level 4 Cable cutters 5 Measur...
Page 3: ...wall where the 4 female brackets are to be positioned It is important to line the male spigot bracket attached to the heater to your markings Using the drill drill 4 holes in the wall and insert wall...
Page 4: ...and secure using the small screw supplied ensuring the spade connections are secured and tight It is recommended that only qualified personnel carry out this Fixing the heater to the female brackets L...
Page 5: ...th wire green yellow into the earth terminal E of the isolating switch When all 3 wires have been terminated to the 230V supply switch is it then safe to turn on the heater The heater will now begin t...
Page 6: ...as shown below a Power specification AC230V 50HZ b Temperature range 0 55o C c Setting temperature range 7 30o C d Time mode 24 hour e Week mode 1 7 f Timing mode Multiple setting 1 hour step g Progr...
Page 7: ...Setting the temperature at 7o C Icon this setting is fixed 3 5 Timing setting Time adjustment adjustment range 0 24H Icon 3 4 Timing mode Timing function Icon 3 6 Programming modes Class II only Six m...
Page 8: ...The default temperature is 19o C As shown Press or to set the temperature press to increase the temperature press to reduce the temperature in 0 5o C steps hold or down to speed the temperature adjust...
Page 9: ...5S every time press to adjust the minute Adjustment range is 0 59 in minute segments Hold down or to increase the adjustment speed Note If there is no activity in 30 seconds the timing setting will e...
Page 10: ...P1 Comfort mode 06 00 22 00 Economy mode all other times outside these times P2 Comfort mode 06 00 09 00 and 16 00 22 00 Economy mode all other times outside these times P3 Comfort mode is 06 00 09 00...
Page 11: ...the day programming modification if there is no activity within 30S 4 2 5 Programming mode It has six programming modes 1 Comfort mode This is your primary heating mode to reach your comfort level Th...
Page 12: ...will appear on the display as shown below The keypad is now locked To unlock the keypad press and hold and for 3 seconds Temperature calibration setting Press for 10 seconds when the heater is in the...
Page 13: ...discretion of Ecovolt replacement with a functionally equivalent product The Ecovolt guarantee is valid for 2 years from the date of purchase of your Ecovolt product or date of delivery The Ecovolt gu...
Page 14: ...olt trained personel of its authorised agents and any parts that are replaced with become the property of Ecovolt Any repairs performed under the guarantee will not extend the guarantee period The Eco...