2.3.3.6.10 The twelve-segment indicator of instantaneous value (3) is used for
fast evaluation of photon-ionizing radiation intensity. The integration time during
measurement of instantaneous intensity value and the time of information update on
the instantaneous value indicator is 500 ms.
2.3.3.6.11 The instantaneous intensity value is displayed in pseudo-logarithmic
scale. The first segment of the indicator becomes highlighted when the intensity
corresponds to 2 cps from the alpha, beta, gamma counter. The greater the intensity
of photon-ionizing radiation, the more segments of the indicator become
highlighted from left to right. The scale becomes fully highlighted when the
intensity equals 3100 cps from the alpha, beta, gamma counter. DER is about
400 μSv/h in this case.
2.3.3.6.12 The sound symbol (4) means that sound signaling of registered
gamma quanta is on. If signaling is on, the sound symbol is displayed on the LCD
and each registered gamma quantum is followed by a short sound signal.
2.3.3.6.13 Enable/disable sounding of registered gamma quanta by a brief press
of SOUND button.
Summary of Contents for STORA-ABG RKS-01
Page 1: ...RKS 01 STORA ABG RADIOMETER DOSIMETER Operating Manual ...
Page 2: ......
Page 24: ...22 ...
Page 27: ...25 Figure 1 2 Appearance of the radiometer top view ...
Page 29: ...27 Figure 1 3 Appearance of the radiometer bottom view ...
Page 64: ...62 Figure 2 5 LCD of the radiometer submode of the alarm threshold level programming ...
Page 70: ...68 Figure 2 8 LCD of the radiometer submode of measurement result saving ...
Page 86: ...84 Figure 2 12 LCD of the radiometer submode of time and date correction time programming ...
Page 88: ...86 Figure 2 13 LCD of the radiometer submode of time and date correction year programming ...
Page 90: ...88 Figure 2 14 LCD of the radiometer submode of time and date correction date programming ...
Page 93: ...91 Figure 2 15 LCD of the radiometer alarm clock mode ...
Page 94: ...92 Figure 2 16 LCD of the radiometer submode of the alarm clock triggering time programming ...
Page 96: ...94 Figure 2 17 LCD of the radiometer submode of the alarm clock triggering time programming ...
Page 99: ...97 Figure 2 18 LCD of the radiometer mode of data communications control with the PC ...
Page 101: ...99 Figure 2 19 LCD of the radiometer mode of data communications control with the PC ...
Page 106: ...104 Figure 2 21 LCD of the radiometer measurement results viewing ...
Page 133: ...131 APPENDIX А Anisotropy horizontal plane Figure А 1 ...
Page 134: ...132 APPENDIX А Anisotropy vertical plane Figure А 2 ...