background image

                     

              

 

Pellet stove

                             ILARIA 

                   

Operation and maintenance manual

                  

www.ecoteck.it

                     

              

 

Pellet stove

    

 

        ILARIA

                   

Operation and maintenance manual

                  

www.ecoteck.it

Summary of Contents for ILARIA

Page 1: ...Pellet stove ILARIA Operation and maintenance manual www ecoteck it Pellet stove ILARIA Operation and maintenance manual www ecoteck it...

Page 2: ...MANUAL MAINTENANCE DATE OPERATION PERFORMED MANUAL ILARIA MAINTENANCE DATE OPERATION PERFORMED ILARIA...

Page 3: ...erforming any operations on the product The manual features a number of icons that highlight the most important instructions 2 2 Important Carefully read this booklet which describes all the steps req...

Page 4: ...d 2 Safety information 3 Introduction 3 1 Liability 3 2 Spare parts 3 3 What are pellets 4 Safety device 4 1 No flame in the fireport 4 2 Temporary power failure 5 Assembly installation and start up 5...

Page 5: ...warranty coupon must be detached and sent within eight days from purchase to ecoteck srl Via Kupfer 3 Palazzolo s O Brescia 25036 27 9 Warranty 9 1 Warranty certificate Ecoteck srl thanks you for the...

Page 6: ...e handle and pipes heat up considerably during operation these parts must only be touched using suitable protective equipment 3 General information The ILARIA pellet stove must only be used in residen...

Page 7: ...irepot daily as not all pellets have the same high quality standard The glass is automatically cleaned by a flow of air nonetheless a slight grey film will tend to form on the glass after a few hours...

Page 8: ...Ash 1 5 Specific weight 1 0 kg dm3 The pellets must be transported and stored completely dry Upon contact with moisture they swell up and can no longer be used Consequently they need to be protected a...

Page 9: ...eat due to the malfunction of the tangential fan the thermostat is activated stopping the feed screw VACUUM SWITCH THERMOSTAT WHIT MANUAL RESET 8 23 23 Only a clean and unblocked firepot will ensure t...

Page 10: ...wing cleaning instructions carefully Failure to follow the instructions may cause operating problems of the stove 8 1 Cleaning the surfaces To clean the surfaces of the painted metal parts use a rag d...

Page 11: ...nveyor 7 5 5 Operating hours menu The ORE LAVORO OPERATING HOURS menu item shows the total operating hours of the stove 7 5 6 Display Settings menu Many of the operating parameters of the stove are lo...

Page 12: ...user and maintenance manual 2 Remove all the equipment placed inside the hopper when packing the stove 20 7 5 2 Timer thermostat The timer thermostat function allows the stove on off times to be set...

Page 13: ...nt and the grease in the tube bundle 6 Tips Do not switch the stove on intermittently This may cause sparks that shorten the life of the electrical components Do not touch the stove with wet hands The...

Page 14: ...pens The stove starts the shutdown procedure after around 10 minutes it will switch off completely MANCA DERESS NO DRAUGHT The alarm is signalled if the draught safety thermostat contact opens The sto...

Page 15: ...to the minimum value of 1 the value is shown on the display P2 Increase heat When in set heat mode or in operating mode and the room temperature is less than the temperature set point this button is u...

Page 16: ...e thermostat opens External thermostat open TAmb TSetTerm The stove works at the set heat output until reaching TSetAmb TAmb TSetAmb after which the economy phase starts TAmb TSetAmb Display The LCD s...