INSTALLATION INFORMATION
The boiler room
The boiler room must comply with applicable building
standards. Ensure a good air supply by having an air
inlet equivalent in size to the flue pipe area.
Chimney
EcoTec MiniQ has a flue pipe connection to the rear. Dif-
fering chimney heights and types, wind and position may
affect its drawing capacity. You should have a vacuum of
10-15 Pa in the boiler to achieve a good function. The
chimney should be at least 120 mm in diameter. The flue
pipe connection must have a damper.
Connection
Pipe installation must be carried out in accordance
with applicable heating and hot-water standards.
Flue pipe connection for damper, to the
rear.
Item no. for damper (optional): 1234-00
Flue pipe connection for damper,
upwards (optional).
Item no. for pipe: 8701-00
Item no. for damper: 1234-00
Temp. sensor for con-
trolling charging units
in submerged pipes
together with sensors for
thermometers and oper-
ating temperature.