Short programming instructions SPÜL 6 - Standard System
3.04/KES1P-
1_0.D
O
C
General
T
he pre-conditioning for the programming of the cont
rols
is the pow
er supply
to the circuit board.
Furthermore, the machine must be sw
itched off completely
(all diodes off)
and
the
programming
blocking device (bridge betw
een terminal 44 and 45
on
the
electronic circuit board) must be
removed. Basically
, the programming is done in three steps.
Selecting the programming mode
One enters the programming mode by
depressing t
he cy
cle start key
until the diode on this
key
blinks tw
ice. T
he programming mode can be ex
ited at
any
time by
depressing once more the cy
cle
st
ar
t key
, in w
h
ich case no alt
e
ra
ti
ons t
o
t
he pr
ogr
am
m
ing w
ill be init
iat
ed.
Selecting of the function
Once in the programming mode,
one enters the function selection
mode. Using the function listing
below
,
the
desired
function can be selected by
depr
essing the selection key
, and confirmed by
using the confirmation key
.
Setting the parameters
After confirming the function, one enters the par
ameter mode (at least one diode above the cy
cle
duration sy
mbols w
ill blink). Using the adjoi
ned
listing, the parameters can be selected and
confirmed. When confirming, the progra
mming mode w
ill be automatically
ex
ited.
CA
UTI
O
N
:
THE A
LTERA
TIONS OF FA
CTORY SET PA
RA
METERS CA
N
A
FFECT
THE
OVERA
LL
FUNCTI
O
N
S
O
F
THE M
A
CHI
NE.
A
LL A
RBI
TRA
R
Y PA
RA
M
E
TER A
LTERA
TI
O
N
PERFO
RM
ED
BY A
N
UNA
UTHO
RI
ZED PA
RTY WI
LL CA
USE THE WA
RRA
NTY TO
BE VO
ID
!
Parameter mode
BT TT
CD
RT WH
A
V
1
A
V
2
M
T
[°C
]
[°C
]
[s]
[s]
[°dH
]
50
40
60
4
0
--
--
Ecostar 430 F
53
42
90
5
8
DP
DT
Ecostar 530 F
56
44
120
6
10
PR
FC
DV 40 N
59
46
160
7
12
DP+PR
DT
+FC
62
48
180
8
14
65
50
240
9
16
68 52
270
10 18
71 54
300
11 20
74 56
330
12 22
77 58
360
13 24
80 60
390
14 26
83 62
420
15 28
86 64
450
17 30
89 66
480
19 32
92 68
510
21 34
--
70
540
23
36
--
72
570
25
38
--
74
600
27
40
--
76
--
30
42
DP
drain pump
DT
detergent dosing by
time
PR
prerinsing
FC
filling continuously
Non-critical faults - (operation still possibl
e within limits; fault is acknowledged by
depressing the "0"-key)
Insufficient detergent dosing
Faulty
boiler i.e. tank heating
Insufficient fresh w
a
ter supply
(PB)
Insufficient drain pump throughput (PB)
Critical faults - (only emergency operation;
fault is acknowledged by depressing the „0“ key)
Broken w
ire or short circuit of the boiler temperature sensor
Broken w
ire or short circuit of the tank temperature sensor
Faulty
conductivity
control
Complete fault - (operation no longer possibl
e; disconnect machine from power supply)
Chip (EEPROM) faulty
, not properly
installed or missing
Function mode
BT
Boiler temperature
TT
T
ank temperature
CD
Cy
cle duration
RT
Rinse t
im
e
WH
Water
hardness
AV
1
Additional variant 1
AV
2
Additional variant 2
MT
Machine ty
pe
0-ke
y
Se
lection
ke
y
Cy
cl
e st
art
k
e
y
On
flas
h
ing
Of
f
In
di
c
a
ti
on
LED
f
o
r p
ro
g
ra
m
m
in
g
m
o
du
s
a
n
d
fa
u
lt
in
d
ic
a
tio
n
Summary of Contents for 430f