CONTROL VALVE PROGRAMMING AND COVER DRAWING MANUAL

4

1. CONTROL VALVE FUNCTION AND CYCLES OF OPERATION

This glass fi lled Noryl

1

 (or equivalent) fully automatic control valve is designed as the primary control 

center to direct and regulate all cycles of a downfl ow regeneration water softener or filter.

The time clock control valve can be set to perform downfl ow regeneration or simply backwash. The time 

clock control valve has two calendar options for regeneration frequency:

1. An option where the user can choose the number of days (1-99) between each regeneration; and.
2. 

A seven-day option where the user can choose which day(s) of the week a regeneration should 

occur.

The control valve is compatible with a variety of regenerants and resin cleaners. The control valve is 
capable of routing the flow of water in the necessary paths to regenerate or backwash water treatment 
systems. The injector regulates the flow of brine or other regenerants. The control valve regulates the 
flow rates for backwashing, rinsing, and the replenishing of treated water into a regenerant tank, when 
applicable.

The control valve uses no traditional fasteners (e.g. screws); instead clips, threaded caps and nuts and 
snap type latches are used. Caps and nuts only need to be firmly hand tightened because radial seals 
are used. Tools required to service the valve include one small blade screw driver, one large blade screw 
driver, pliers and a pair of hands. A plastic wrench is available which eliminates the need for screwdrivers 
and pliers. Disassembly for servicing takes much less time than com pa ra ble products currently on the 
market. Control valve installation is made easy because the distributor tube can be cut ½” above to ½” 
below the top of tank thread. The distributor tube is held in place by an o-ring seal and the control valve 
also has a bayonet lock feature for upper distributor baskets.

The power supply comes with a 15 foot power cord and is designed for use with the control valve. The 
power supply is for dry location use only. The control valve maintains timekeeping for up to 8 hours if the 
power goes out and the battery is not depleted. After 8 hours, the only item that needs to be reset is the 
time of day; valve status and programming are permanently stored in the nonvolatile memory. If a power 
loss lasts less than 8 hours and the time flashes on and off, the time of day should be reset and the non 
rechargeable battery should be replaced.

Table  1  shows  the  time  for  the  backwash,  regenerative,  and  rinse  cycles  for  the  ten  available 
programming options. Six different programs are available for a softener, one for a regenerative filter, 
and three programs for backwash only filters. When the control valve is used as a:

• Softener - one or two backwashes occur and refill always occurs after the rinse cycle (P0 through P5)
• Regenerative Filter - one backwash occurs and refill always occurs after the rinse cycle (P6)

• Backwashing Filter - one backwash occurs (P7 through P9)

• The user can initiate manual regeneration. The user has the option to request the manual regeneration 

at  the  delayed  regeneration  time  or  to  have  the  regeneration  occur  immediately.  Simultaneously 
press ▲ and ▼ to start a regeneration at the next delayed regeneration time. If a regeneration is to 
occur “today” an arrow will point to REGEN. For immediate regeneration, simultaneously press and 
hold ▲ and ▼ for three seconds.

When in regeneration, step through the different regeneration cycles by pressing ▲ or ▼.

1

 Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company

Summary of Contents for WS1 CT

Page 1: ...Control Valve Programming and Cover Drawing Manual Models ECOSOFT WS1 CT WS1 25 CT...

Page 2: ...CERTIFICATES OF ECOSOFT ECOSOFT 9001 2015...

Page 3: ...G MANUAL ENG 1 Control Valve Function and Cycles of Operation 4 2 OEM General Programming Instructions 5 3 User Displays Settings 6 4 OEM System Setup 7 5 Installer Displays Settings 7 6 Drawings of C...

Page 4: ...use the distributor tube can be cut above to below the top of tank thread The distributor tube is held in place by an o ring seal and the control valve also has a bayonet lock feature for upper distri...

Page 5: ...minute time out are incorporated To quickly exit Installer Displays Settings or OEM Setup simultaneously press SET Any changes made prior to the exit are incorporated To reinitialize the control valv...

Page 6: ...8 00 12 10 Regen Min Fill Regen Time Time PM Days To Regen SET 2 00 Regen Min Fill Regen Time Time PM Days To Regen SET e2 Regen Min Fill Regen Time Time PM Days To Regen SET 12 00 Regen Min Fill Rege...

Page 7: ...without the PM indicator Press SET to go to Step 3U STEP 3IU Step 3IU C249 Regen Min Fill Regen Time Time PM Days To Regen SET SET 12 10 Regen Min Fill Regen Time Time PM Days To Regen SET 2 00 Regen...

Page 8: ...Fill Regen Time Time PM Days To Regen SET P 1 Regen Min Fill Regen Time Time PM Days To Regen SET Regen Min Fill Regen Time Time PM Days To Regen SET 99 Regen Min Fill Regen Time Time PM Days To Rege...

Page 9: ...ys To Regen SET 5 Regen Min Fill Regen Time Time PM Days To Regen SET 6 Regen Min Fill Regen Time Time PM Days To Regen SET 7 Regeneration Time Minutes Set the time for regeneration to start using or...

Page 10: ...I7 Time PM Days To Regen Time PM Days To Regen Time PM Days To Regen Regen Min Fill Regen Time Time PM Days To Regen SET 1 Regen Min Fill Regen Time Time PM Days To Regen SET 2 Regen Min Fill Regen Ti...

Page 11: ...07 01 WS1 Motor 1 3 V3106 01 WS1 Drive Bracket Spring Clip 1 4 V3108TC WS1 TC PC Board 1 5 V3110 WS1 Drive Gear 12 x 36 3 6 V3109 WS1 Drive Gear Cover 1 V3002TC WS1 TC Drive ASY Not Shown V3186 WS1 AC...

Page 12: ...y 1 V3005 WS1 Spacer Stack Assembly 1 2 V3004 Drive Cap ASY 1 3 V3178 WS1 Drive Back Plate 1 4 V3011 WS1 Piston Downflow ASY 1 5 V3174 WS1 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O ring 337 1...

Page 13: ...jector ASY B BROWN V3010 1C WS1 Injector ASY C VIOLET V3010 1D WS1 Injector ASY D RED V3010 1E WS1 Injector ASY E WHITE V3010 1F WS1 Injector ASY F BLUE V3010 1G WS1 Injector ASY G YELLOW V3010 1H WS1...

Page 14: ...Locking Clip 1 3 JCP P 6 Polytube insert 3 8 1 4 JCPG 6PBLK Nut 3 8 1 5 H4613 Elbow Cap 3 8 1 6 V3163 O ring 019 1 7 V3165 01 WS1 RFC Retainer ASY 1 8 V3182 WS1 RFC 1 Not Shown H4650 Elbow 1 2 with n...

Page 15: ...for 3 4 V3162 017 WS1 DLFC 1 7 gpm for 3 4 V3162 022 WS1 DLFC 2 2 gom for 3 4 V3162 027 WS1 DLFC 2 7 gpm for 3 4 V3162 032 WS1 DLFC 3 2 gpm for 3 4 V3162 042 WS1 DLFC 4 2 gpm for 3 4 V3162 053 WS1 DL...

Page 16: ...V3150 WS1 Split Ring 1 7 V3151 WS1 Nut 1 QC 1 8 V3105 O ring 215 1 9 V3190 090 WS1 DLFC 9 0 gpm for 1 One DLFC must be used if 1 fitting is used V3190 100 WS1 DLFC 10 0 gpm for 1 V3190 110 WS1 DLFC 1...

Page 17: ...17 1 11 2 12 3 13 4 15 5 16 6 17 7 18 8 20 9 28...

Page 18: ...1 25 CT 1 1 2 5 1 1 7 6 13 3 6 13 3 8 0 3 7 2 3 1 4 8 6 4 43 1 3 4 1 3 8 1 2 2 187 50 1 32 3 4 1 3 8 1 2 2 187 50 2 220 50 12 500 6 21 6 24 6 21 1 1 2 3 2 4 5 6 3 14 6 70 3 12 3 12 1 99 1 ECOSOFT WS1...

Page 19: ...19 ECOSOFT WS WS1 WS125 1 2 B L F C 3 D L F C 4 5 24V DC 6 7 2 SET HOUR...

Page 20: ...Min Fill Regen Time SET 2 0 Regen Min Fill Regen Time SET Regen Min Fill Regen Time SET C249 Regen Min Fill Regen Time Time PM Days To Regen SET Regen Min Fill Regen Time Time PM Days To Regen SET 8 0...

Page 21: ...gen Time Time PM Days To Regen SET 4 2 0 Regen Min Fill Regen Time SET Regen Min Fill Regen Time SET 24 SET HOUR STEP 3IU 3IU C249 Regen Min Fill Regen Time Time PM Days To Regen SET SET 12 10 Regen M...

Page 22: ...22 4 2 1 2 2 5 5 SET HOUR...

Page 23: ...23 5 10 2 1 backwash 2 dn brine 3 backwash 4 rinse 5 fill 1 2 3 4 5 0 3 50 3 3 1 99 P1 8 50 8 4 1 99 2 8 70 10 6 1 99 12 70 12 8 1 99 4 10 50 8 1 99 5 4 50 4 1 99 12 6 12 1 99 7 6 4 8 10 6 9 14 8...

Page 24: ...in Fill Regen Time SET Regen Min Fill Regen Time SET Regen Min Fill Regen Time SET Regen Min Fill Regen Time SET Regen Min Fill Regen Time SET Regen Min Fill Regen Time SET 1 6 1 2 0 65 7 9 SET HOUR 4...

Page 25: ...Time Time PM Days To Regen SET 3 Regen Min Fill Regen Time Time PM Days To Regen SET 4 Regen Min Fill Regen Time Time PM Days To Regen SET 5 Regen Min Fill Regen Time Time PM Days To Regen SET 6 Regen...

Page 26: ...ays To Regen SET 6 Regen Min Fill Regen Time Time PM Days To Regen SET 7 SET HOUR 8I7 STEP 8I7 8I7 Time PM Days To Regen Time PM Days To Regen Time PM Days To Regen Regen Min Fill Regen Time Time PM D...

Page 27: ...27 8 8 8 E1 E2 E3 E1 2 SET HOUR SET HOUR...

Page 28: ...28 8 SET HOUR...

Page 29: ..._______________________ ECOSOFT WS____CT VLV BND __________________________ 12 __________________________ 12 __________________________ __________________________...

Page 30: ......

Page 31: ......

Page 32: ...ecosoft com...

Reviews: