2. SPECIFICATIONS AND COMPONENTS  

 

2.1 TECHNICAL SPECIFICATIONS 

 

Parameter 

Value 

Purified water flow rate 
@ 25 °C, 1000 mg/l total dissolved solids feed water 

55…60 l/h 

Feed water flow rate 

110…130 l/h 

Concentrate flow rate 

55…65 l/h 

Inlet water pressure 

2,0…5,0 bar* 

Operating pressure in membrane array 

5,0…7,0 bar 

Pressure in tank bladder (when used with pressure tank) 

0,4…0,6 bar 

Feed water temperature 

+4… +30 °C** 

Ambient air temperature 

+5…+40 °C** 

Connection to water mains 

½″ thread 

10  Overall dimensions, H × W × D (base model) 

420×220×425 
mm  

11  Weight (base model) 

6 kg 

12  Electrical rating 

230 V, 50 Hz 

13  Power consumption, max. 

80 W 

14  Ingress protection rating 

IP 54 

* If pressure of water in your system does not meet requirement, install a pressure booster pump to raise it. 

If water pressure exceeds the upper limit, install a pressure regulator before the Robust system. 

**  Using  the  Robust  system  with  feed  water  temperature  between  +20  and  +30  °С  produces  a  lower 

rejection  rate  and  higher  flow  rate,  which  yields  higher  TDS  of  purified  water.  Using  the  system  with  feed 

water above +30 °С is advised against. 

2.2 FEED WATER REQUIREMENTS* 

 

Parameter 

Value** 

pH 

6,5…8,5 

Total dissolved solids (TDS) 

< 1500 mg/l 


 

Hardness 
 

< 30 °dH (500 
mg CaCO /l) 


 

Residual chlorine 
 

< 0,5 mg/l 
 

Iron 

< 0,3 mg/l 

Manganese 

< 0,1 mg/l 


 

Chemical oxygen demand 
 

< 5 mg O

2

/l 

 


 

Total microbial count 
 

< 100 CFU/ml 
 


 

E. coli 

none 
 

* If feed water quality does not meet specified requirements, membrane and filter service life may decrease.  

**  If  aiming  to  purify  raw  water  (well  water/ground  water  etc),  it  is  recommended  to  carry  out  detailed 

water  analysis.  If  any  constituents  exceed  the  above  limitations,  it  is  advisable  to  install  a  special  filter 

upstream  of  your  reverse  osmosis  system.  Consult  professional  water  treatment  specialist  for  proper 

selection of an appropriate filter for your water. 

Summary of Contents for Robust

Page 1: ...ECOSOFT Robust Reverse osmosis system Installation and operation manual...

Page 2: ...Instruction manual for ECOSOFT Robust reverse osmosis system 2 This manual is the intellectual property of and copyrighted by ECOSOFT SPC LLC Copying and reprinting is forbidden 2015...

Page 3: ...Robust with pressure tank 9 3 3 ECOSOFT Robust with pressure tank and ultraviolet unit 10 4 Installation steps 10 4 1 Installation conditions and package completeness check 10 4 2 Installation 11 5 Po...

Page 4: ...n capable multistage reverse osmosis system The system can be equipped with a pressure tank for increasing purified water flow rate and multistage design allows to obtain a high recovery of up to 50 T...

Page 5: ...rified water line may go to purified water faucet or be connected with some other consumer appliance High pressure switch installed before the postfilter reads pressure in permeate line and starts the...

Page 6: ...nd occurring problems Direct flow capacity of Robust system is 55 60 l h If the required peak flow is greater than that the system can be equipped with a pressure tank which can be connected with the...

Page 7: ...nt install a pressure booster pump to raise it If water pressure exceeds the upper limit install a pressure regulator before the Robust system Using the Robust system with feed water temperature betwe...

Page 8: ...ith booster pump 2 Prefilters and postfilter 3 Reverse osmosis membranes 4 Feed adapter 5 Feed valve 6 Drain saddle 7 Colored tubing 8 Purified water faucet 9 Filter bowl wrenches OPTIONS 10 Mineraliz...

Page 9: ...ECOSOFT Robust base model 3 2 ECOSOFT Robust with pressure tank Connections Purified water Run blue tube from purified water port to purified water faucet Drain Run black tube from drain port to drain...

Page 10: ...eck that all components of the reverse osmosis system see p 2 3 are inside the package Do not open plastic bag before you make sure it contains all parts Missing part claims will not be accepted if th...

Page 11: ...een factory tested for leaks and may contain residual moisture Before installation of tubing filters and membranes wash your hands with antibacterial soap Ensure that the installation place is shielde...

Page 12: ...ther end of black tube with drain port of the RO system s push fit port rack 6 Put a few turns of PTFE tape on tank nipple thread Screw tank valve on the tank nipple Turn the valve fully off NOTE Test...

Page 13: ...there are no carbon fines in rinsewater Install the free tube ends back in push fit fittings in membrane housings and lock with locking clips 11 Install carbon postfilter in 3rd filter housing from t...

Page 14: ...er solenoid The system must switch off and stop discharging concentrate when pressure tank is full and purified water faucet is closed 3 Inspect the system carefully for leaks 4 Advise the system s ow...

Page 15: ...ended to shut off the water supply Recommendations on the front panel plate indicate what actions should be undertaken if abnormal pressure is read on pressure gauges Pressure after prefilters 1st pre...

Page 16: ...ater 6 2 FILTER REPLACEMENT 1 Open purified water faucet 8 while the system is plugged in close feed water valve 5 close pressure tank 12 valve if installed 2 Wash your hands with antibacterial soap t...

Page 17: ...inside the housings 4 Take new membranes and grease their brine seals and membrane housing cap O ring seals Caution Only use food grade glycerol or certified RO membrane compatible lubricant for grea...

Page 18: ...ill with water and screw it back on filter head 6 Let stand for 15 minutes then open feed valve and purified water faucet and plug in the mains 7 When water coming out of purified water faucet starts...

Page 19: ...ified water faucet and drain all chlorinated water from the tank by opening purified water faucet Open feed water valve and flush the system until chlorine smell disappears Close feed water valve and...

Page 20: ...es Replace membranes Bent flexible tube Inspect the tubing and straighten if necessary Purified water runs normally for a few seconds then slows down to a trickle in a pressure tank equipped system De...

Page 21: ...r a few minutes Air bubbles trapped in the system Some air may remain in the system for a few days after installation and will go away on its own Air bubbles may appear in water if there is a large di...

Page 22: ...ate of commissioning Water pressure at the inlet bar Carbon fines fully flushed from filters Y N Preservative fully flushed from membranes Y N System disinfected Y N Water pressure in membrane array b...

Page 23: ...filters Y N Preservative fully flushed from membranes Y N Water pressure at the inlet bar Water pressure in membrane array bar Air pressure in pressure tank bladder bar Feed water temperature C Purifi...

Page 24: ...ype of transport Observe handling labels when handling and shipping the product The product should be stored indoors protected from mechanical damage moisture and aggressive chemicals in vendor s orig...

Page 25: ...malfunctions arising due to non timely replacement of spent consumables that exceeds terms indicated in this manual and use of consumables from other vendors Claims of water quality issues including...

Page 26: ...ng special tools to work cast iron artificial stone ceramics etc pressure regulator installation pulsation damper installation water leak detection system installation installation of other auxiliary...

Page 27: ...ust reverse osmosis system 27 This manual is the intellectual property of and copyrighted by ECOSOFT SPC LLC Copying and reprinting is forbidden 2015 14 AUTHORIZED SERVICES IN YOUR AREA Name Address C...

Page 28: ......

Reviews: