Replacement Parts 

Replacement Parts HVP Models 

Item 

Part Number 

Part Number 

Part Number 

Description 

Qty. 

 

50HVP 

90HVP 

120HVP 

 

 

METALWORK 

16028 

16023 

16058 

Wrapper 

16029 

16024 

16060 

Bottom cover 

16039 

16040 

16052 

Top cover 

16016 

16003 

16056 

Centre plate 

16005 

16005 

16005 

Coil rail 

16036 

16006 

16036 

Electrical box support 

16007 

16007 

16007 

Electrical box 

16008 

16008 

16008 

Electrical box cover 

16031 

16026 

16062 

Upper door 

10 

16032 

16027 

16064 

Lower door 

 

 

 

 

 

 

BLOWER ASSY 

11 

16033 

16004 

16055 

Blower assy 

12 

16035 

16035 

16035 

Motor mount set BB-10-4 (short 
arm) 

 

 

 

 

 

 

ELECTRICAL 

13 

18010 

18010 

18010 

Relay 24VAC 10A contact SPST 

14 

18000 

18000 

18000 

Door Switch 

15 

1501450 

1501590 

15014120 

PCA Ecosmart HVP Controller 

16 

18001 

18001 

18001 

Transformer 120VAC 24VAC 
40VA 

17 

18008 

18009 

18009 

Motor EC Perfect Speed 1800 

18 

18011 

18011 

18011 

Barrier block 20A 4 pos 

19 

18020 

18020 

18020 

Fuse 3A 

 

 

 

 

 

 

WIRING 

20 

20000 

20000 

20000 

Cable assy temp sensor 10K 

21 

20001 

20001 

20001 

Cable assy motor control 

22 

20002 

20002 

20002 

Cable assy motor power 

23 

20008 

20008 

20008 

Cable assy temp sensor 
extension 

24 

20009 

20009 

20009 

Cable assy supply temp sensor 

 

 

 

 

 

 

Summary of Contents for ES50HVP

Page 1: ...P N 14010A ES50HVP ES90HVP HIGH VELOCITY AIR HANDLER Service Manual Ecosmartair 105 Haist Avenue Unit 10 Vaughan ON L4L 5V6 905 857 9755 ecosmartair com ...

Page 2: ...1 P a g e ...

Page 3: ... does not run electrical issue 7 External pump is noisy at start up 7 Water heater temperature and pressure relief valve is weeping 7 Insufficient or no heat 7 Cold water at hot faucet 7 Heating during standby mode 8 Pump and fan run continuously test mode off and no call for heat cool 8 Constant Pressure Sensing CPT not working 8 Final Assembly Exploded View 10 Electrical Box Exploded View 11 Blo...

Page 4: ...3 P a g e CONTROL ASSEMBLY LAYOUT Figure 1 HVP Control Assembly 3 15 10 16 9 7 6 5 4 8 14 1 2 13 17 11 12 18 19 20 Tubing connects to right hand port ...

Page 5: ...ater priority 8 Air in out temperature sensors 9 Fuse 3A 32V ATO type 10 Pressure sensor 11 Heat cool CFM DIP switches 12 Options DIP switches 13 Door switch 14 Pump relay 15 24VAC output from transformer Blue R Yellow C For smart WiFi thermostats requiring constant power such as Nest Ecobee CÔR etc use C connection at yellow wire using a double male female adapter 0 25 Do not connect thermostat t...

Page 6: ... 2 1 4 20 bolts lock washers and flat washers Slide out blower assembly TROUBLESHOOTING Smart WiFi thermostat not working properly Standard digital thermostats usually have internal batteries and do not require external power Smart thermostats require a constant source of external power to operate internal electronics This power is derived from a C connection that is available at all times Do not ...

Page 7: ... check for 120VAC on power connector at motor 2 If power is not present check door switch 13 3 If power is still not present check continuity of motor power cable 4 Unplug motor control cable at connector 19 5 Connect PWM tester to the control board EC motor connector 19 with same orientation as motor control cable 6 Jumper R to G to bring on fan 7 The PWM tester should gradually increase in brigh...

Page 8: ...ping A check valve or back flow preventer may have been installed in the system Some form of pressure relief is required Inspect expansion tank for defects If the system does not have an expansion tank install one Insufficient or no heat Check that the heat generator is functioning properly Plugged air filter or coil Refer to maintenance section for filter care and coil cleaning Air in heating loo...

Page 9: ...thin the ductwork irrespective of outlet vents opening and closing when in heating mode CPT is designed to reduce airflow noise caused when vents are partially or fully closed CPT is unavailable when in cooling mode to prevent potential freezing of the DX coil To enable the CPT function follow the steps below STEP 1 Set desired heat airflow rate using the HEAT DIP switch 11 STEP 2 Set OPTION switc...

Page 10: ... no debris blocking the tube or the plastic inlet T located on the centre plate If the system still does not work then sensor is defective and the board needs to be replaced As a workaround until the board is replaced set OPTIONS switch 4 to the off position and the ecosmart will run in fixed airflow mode ...

Page 11: ...10 P a g e Final Assembly Exploded View 10 9 1 3 2 8 4 6 11 26 25 5 7 27 28 A 34 32 31 30 3 40 39 41 A ...

Page 12: ...11 P a g e Electrical Box Exploded View 16 27 15 26 13 18 14 29 33 20 7 38 36 23 19 33 ...

Page 13: ...12 P a g e Blower Heating Coil Exploded View 11 21 17 12 22 35 27 37 25 24 37 37 ...

Page 14: ...BLOWER ASSY 11 16033 16004 16055 Blower assy 1 12 16035 16035 16035 Motor mount set BB 10 4 short arm 1 ELECTRICAL 13 18010 18010 18010 Relay 24VAC 10A contact SPST 1 14 18000 18000 18000 Door Switch 1 15 1501450 1501590 15014120 PCA Ecosmart HVP Controller 1 16 18001 18001 18001 Transformer 120VAC 24VAC 40VA 1 17 18008 18009 18009 Motor EC Perfect Speed 1800 1 18 18011 18011 18011 Barrier block 2...

Page 15: ...31 19016 19016 19016 Lockwasher 1 4in zinc 2 32 19017 19017 19017 Washer 1 4in zinc 2 33 19012 19012 19012 Bushing universal 0 875 blk 5 34 19007 19008 19008 Dome plug blk 2 35 19013 19013 19013 Cable clip 7 16in blk 1 36 19014 19014 19014 Cable clip 3 16in blk 1 37 19003 19003 19003 Grommet 0 625OD 0 312ID blk 4 38 19004 19004 19004 Control board support 7 MISC 39 19024 19024 19024 Silicone Tubin...

Reviews: