background image

 

Range 2 

– MB04 

Operating instructions

 

 

TRIONYX | Date du document : 18/04/2019 – Version : 01 

 

Transport and handling 

 

The safety cabinet that you received has been protected and transported in optimal conditions, as to be protected from any damage.  

It has to be lifted only by suitable equipment (suct

ion cup, strap…). It has to be carried in a vertical position, and it must not be lying.  

It is imperative not to tilt the cabinet when it is carried. Indeed it can cause damages that can alter the right functioning of the cabinet.  

On the other hand, if it has to be moved, the cabinet has to be placed on a pallet and strapped, as to avoid any fall.  

 

Commissioning 

 

After having unwrapped the cabinet, ensure that you also received a set of two keys.  

Your safety cabinet has to be installed, used and maintained as to guarantee the users protection.  

You need to remove the covers on the vents before storing any can in your cabinet. To do this, simply unscrew them counterclockwise.  

The doors open by pulling the handle towards you.  

 

4.  INTERNAL EQUIPMENTS 

 

The cabinet is provided with 1 shelf. This must be fixed at the chosen height thanks to the rack and pinion.  

Take care not to exceed the loading capacity per shelf of 159 KG.  

The cabinet also has an integrated retention tank, which has a retention capacity of 6 liters.  

 

5.  STORAGE 

 

Your safety cabinet is exclusively destined to store chemicals in laboratories, industries, schools

… in closed containers.  

It must not store high concentrated corrosive products.  

We remind  you  that  the  storage  of corrosives  can  alter  the  quality  of  your safety  equipment.  On  the  other  hand,  we  remind  you  that 

damages due to a bad use of the equipment and in particular to corrosion won

’t be covered by our warranty.  

 

6.  VENTILATION 

 

We highly recommend connecting your safety cabinet to a ventilation system, as to evacuate the eventual vapors contained in it.  

The air renewal has to be at least 10 times the volume of the cabinet, per hour. Moreover, ensure that the ventilation runs 24h/7.  

 

Connection to a ventilation system 

The air inlet and outlet are situated on the side of the cabinet.  

How to choose a ventilation or a filtration box ?  

 

Ventilation boxes

 are connected to the safety cabinet with a connecting kit (including a connecting sleeve, 2 hose clamps and 1 meter 

of  flexible  sheath)  ;  the  fan  included  in  the  box  extracts  the  toxic  vapors  contained  in  the  cabinet,  and  reject  it  to  the  outside  of  the 

building thanks to the roof or wall extraction.   

 

If you cannot reject the vapors to the outside, you need a filtration box.  

 

Summary of Contents for MB04

Page 1: ...Range 2 MB04 Operating instructions TRIONYX Date du document 18 04 2019 Version 01 0 Instruction manual For safety cabinet Model MB04 ...

Page 2: ...ONTENT 1 Description Use Page 2 2 Technical features Page 2 3 Installation and commissioning Page 2 4 Internal equipments Page 3 5 Storage Page 3 6 Ventilation Page 3 7 Safety controls Page 4 8 Spare parts Page 4 9 Recycling Page 4 10 Warranty Page 5 11 Control sheet for the user Page 6 ...

Page 3: ...centers for versatile storage Leakproof 2 51 mm bottom sump Dual vents with flame arresters 4 self leveling feet Grounding connector External dimensions H 610 x W 430 x D 430 mm Internal dimensions H 465 x W 345 x D 360 mm Storage capacity 15 liters Retention capacity 6 liters Loading capacity 159 KG per shelf Weight 30 KG 3 INSTALLATION AND COMMISSIONING Installation The safety cabinet has to be ...

Page 4: ...the loading capacity per shelf of 159 KG The cabinet also has an integrated retention tank which has a retention capacity of 6 liters 5 STORAGE Your safety cabinet is exclusively destined to store chemicals in laboratories industries schools in closed containers It must not store high concentrated corrosive products We remind you that the storage of corrosives can alter the quality of your safety ...

Page 5: ...ded 7 SAFETY CONTROLS Your safety cabinet is a safety equipment As to guarantee its perfect efficiency you have to check the equipment regularly Daily safety controls Check if the products liquids powders have flowed in the containment sumps If it has they have to be emptied and cleaned promptly with suitable equipment absorbent mat Check that the cabinet and its internal equipments are not corrod...

Page 6: ...ouse The spare parts are under 3 months warranty upon their settlement The warranty cannot be applied in the following cases The equipment has not been stored used or maintained in accordance with the standards by the user In case of a damage of the equipment by the user or a third party The equipment had a modification or a repair by the user or a third party without any prior written authorizati...

Page 7: ...y The locking system of the doors works correctly The mechanic ventilation system is running correctly if applicable The ventilation system is not obstructed The air inlet and outlet are clean The standardized pictogram on the door is in good condition and visible The door hinges are lubricated The locking system is lubricated The containment sump is clean Remarks Date By Signature ...

Reviews: