MAINTENANCE

Periodic maintenance is required to insure that the Living Air Classic operates
properly. A severely polluted environment can foul an Ecotech purification plate in
as little as two weeks or as long as a year. Shown here are basic maintenance
procedures that should be carried out to keep your unit running at top performance.

EcoHelp filter cleaning:

You have two options to clean the carbon lint screen:

• When visibly dirty, simply remove the lint screen and with a hand-held vacuum
remove the heavy particulate from the screen. This method will extend the life of the
filter.

-OR- 

• When visibly dirty, remove the lint screen from the back of the unit and wash in hot
water, brushing gently with a toothbrush to remove particulate. Allow to dry prior to
re-installing the lint screen.

Ecotech purification plate

Carefully remove the Ecotech
purification plate from the
card cage by grasping the
middle of the edge nearest to
you, and slowly  pulling
straight out.

Clean the plate with hot water
and ammonia. Dry completely
using a hair dryer if necessary.
Reinstall plate. Be sure to

check that the electrical tabs are in contact with the plate.

Plate Card Cage

Also be sure to clean the white stand-offs at the
corners of the plate card cage. (A cotton swab with
alcohol works well.)

Fan Blade and Front Grill

Wipe off fan blade and front grill if dirty with damp
washcloth. The fan requires no maintenance (with the
exception of the first time it is used, when it may be
necessary to give it a gentle push to get it started). If
the fan squeaks, a drop of lightweight oil may be
needed on the fan shaft.

Summary of Contents for LIVING AIR CLASSIC

Page 1: ...ly for proper procedures and operation Application Notable Features Specifications Installation Operation Maintenance Warranty Living Air Classic Electronic Air Purification 100 110 and 220 volt Systems EcoQuest International 310 T Elmer Cox Drive Greeneville TN 37743 423 638 7246 www EcoQuest com ...

Page 2: ...ir Classic Serial __________________________________________________________ Please record the name and phone of your EcoQuest Dealer Name ____________________________________________________________ Phone ____________________________________________________________ CAUTION Disconnect power cord before servicing 100 110 volt models use 1 0 Amp slow blow fuse 220 volt models use 0 5 Amp slow blow f...

Page 3: ...ations Positive Negative Ion Generation Technology Ozone Generation Features Adjustable fan speed control Washable lint screen filter Adjustable ozone control Electrical 100 volt 50 60Hz 110 volt 60Hz or 220 volt 50Hz ac line operation depending on model 30 watts power consumption 24 to 30 KV 20 30 Khz ion generation pulsator Fixed 6 KV DC needle ion generator Mechanical 400 CFM fan Size Height 11...

Page 4: ... filtering it masking the symptoms or attempting to dilute it PRE INSTALLATION AND INSPECTION 1 Remove unit from shipping carton 2 Remove all protective materials 3 Check for shipping damage and loose or broken parts 4 Read Owners Manual thoroughly prior to installation 5 Remove Ecotech purification plate from the box and install 6 OPTIONAL Plug the unit into a 110 volt 100 or 220 volt outlet plac...

Page 5: ...late cage between the posts and clips making sure the metal clip on each side of the plate is in contact with the metal screen on the plate 4 Re install Lint Screen as shown below LINT SCREEN INSTALLATION 1 Always install bottom of Lint Screen first 2 The Lint Screen tab should depress the safety switch arm towards the bottom of the unit Unit will not operate if safety switch is not depressed 3 Fi...

Page 6: ...roughly circulate clean air throughout the area 3 In the area most heavily used to achieve maximum benefit Note For maximum control the unit should be placed where easy access to the controls is possible The rear of the unit should always have at least one inch of open area to allow unrestricted airflow Be sure power cord is not accessible to small children to prevent injury EcoHelp HEPA LIKE FILT...

Page 7: ...onment 2 Keeping in mind the previous statement 1 adjust the purifier so that the odor of ozone fades into the background 15 30 seconds after entering the environment 3 NORMAL LOW SWITCH 100 110 volt models only For better purifier control in small areas under 300 square feet set the NORMAL LOW switch to LOW The purifier output will be effective for 1 10th of the area indicated by the current puri...

Page 8: ...with a toothbrush to remove particulate Allow to dry prior to re installing the lint screen Ecotech purification plate Carefully remove the Ecotech purification plate from the card cage by grasping the middle of the edge nearest to you and slowly pulling straight out Clean the plate with hot water and ammonia Dry completely using a hair dryer if necessary Reinstall plate Be sure to check that the ...

Page 9: ...uminated as long as the unit is turned on REPLACING THE FUSE A fuse holder is located on the back of the unit next to the power cord To replace or check the fuse unscrew the fuse holder cap by turning it counterclockwise then remove the cap and fuse If the fuse is blown replace with a new slow blow type fuse Insert the new fuse into the fuse holder and replace the fuse holder cap If the fuse holde...

Page 10: ...e been performed according to the Maintenance section page 8 of this Owner s Manual Order new plates from your Dealer Electrical stainless steel contacts are not contacting the screen portion of the Ecotech purification plate Inspect the unit for any loose connections Do not attempt to disassemble the unit due to the Limited Warranty of the product 3 How am I able to know if the Frequency Type Ion...

Page 11: ...or lack of air movement Symptom Visual haze of smoke and or particulate remain within the environment Problem Lack of ionization and or air movement 6 Unit does not operate Is the unit plugged in Are you sure the outlet is active Is the unit turned on Is the EcoHelp filter installed properly to depress the safety switch downward 7 Air flow is restricted or reduced Is the unit properly placed away ...

Page 12: ...or specific details If you have any questions concerning your Living Air Classic system please see your local EcoQuest Dealer If your unit is defective please contact EcoQuest International 310 T Elmer Cox Drive Greeneville TN 37743 or visit www EcoQuestIntl com for technical help Did you forget to register your Living Air Classic By registering you ll activate your warranty and your privacy is gu...

Reviews: