PURIFIER PLATE:
Remove the rear lint screen (see pages 14 - 17). Carefully remove the
purifier plate from the card cage by grasping the middle of the edge
nearest to you, and slowly pull it straight out.
If you are in an environment where there are fats, oils, or grease,
such as in a kitchen, start by cleaning with denatured alcohol and a
soft bristle brush. This will cut the grease without leaving a residue.
For all applications - Clean with a mixture of one part water and
one part ammonia to remove contaminants. Place the plate into
a shallow dish and pour enough of the water/ammonia solution
into the dish to just cover plate. Allow the plate to soak for no more
than 10 minutes.
CAUTION: Damage may result from soaking the purifier plate
longer than 10 minutes.
Remove plate and scrub with a soft bristle brush. Rinse thoroughly.
Let air dry for 24 hours or use a blow dryer to dry thoroughly.
The unit will display a REPLACE PLATE message if the purification
plate needs to be replaced.
100 & 110 volt models - use 1.6
Amp slow blow fuse.
220/240 volt models - use 1.0 Amp slow blow fuse.
CHANGING THE RCI CELL:
The RCI cell should be changed when REPLACE RCI CELL
appears on the display, or
every three (3) years
, whichever
comes first. To change the RCI cell, follow the instructions on
pages 14 - 17.
CHANGING THE FUSE:
The fuse may be accessed by unplugging the cord from the
back of the unit then pulling, or if necessary, gently prying the
fuse out using a small, straight screwdriver.