Your DuctwoRx

 unit requires no periodic maintenance 

beyond normal replacement of the RCI cell every 3 years.

Note: For optimal performance, EcoQuest recommends 
the replacement of the RCI cell every 3 years, even if the 
UV lamp appears to be operating normally. 

The UV lamp operation indicator on the face of the unit 
will glow when the UV lamp is in use. If the indicator 
does not glow and the unit has power, the RCI cell 
should be replaced.

UV lamp operation indicator

Please do not throw a used RCI cell into the 
garbage. The special germicidal UVX bulb used 
in the DuctwoRx

 contains a very small amount 

of mercury. You may return your used RCI cell to 
EcoQuest for proper disposal. Send the used cell post 
paid to:

DISPOSAL OF THE RCI™ CELL

10

11

7

7. Secure with 2 screws.

8

1

3

3.  Remove the unit from the mounting plate.

4

4.  Remove the 2 screws holding the RCI Cell.

1.  Unplug unit. If the unit is hard wired, be 

sure the power to the unit is off.

10

10.  Reconnect 

power supply.

9

9. Secure unit with 4 nuts.

2

2.  Remove the 4 mounting nuts.

8.  Insert the unit into the mounting plate.

6

6.  Plug the new RCI cell into the base unit.

5

5. Separate the used RCI cell from the 

base unit and dispose of properly.

CHANGING THE RCI

 CELL

EcoQuest International

RCI Disposal
55 Marley Drive
Greeneville, TN 37743

MAINTENANCE/UV LAMP INDICATOR

Did you forget to register your Fresh Air DuctwoRx

?

By registering, you’ll activate your warranty, and your privacy is guaranteed. Just fill 
out your warranty card and drop it in the mail.

WARRANTY INFORMATION

This product is of solid state construction and is warrantied by 
EcoQuest International 
310 T. Elmer Cox Drive 
Greeneville, TN 37743
to the original purchaser, depending on model, to be free from defect in materials 
and workmanship for a limited time. Length of warranty will vary depending on 
model. See warranty card for specific details. If you have any questions concerning 
your Fresh Air DuctwoRx

, please see your local EcoQuest Dealer.

For help, visit www.EcoQuest.com.

WARNING!

 - UV Light in operation. Disconnect unit from power 

supply before servicing. Failure to follow warnings may result in 
severe eye damage.

Summary of Contents for Fresh Air DuctwoRx

Page 1: ...armful interference to radio or television which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is c...

Page 2: ...ilable from your EcoQuest Dealer If you have any questions concerning this or any EcoQuest product contact your EcoQuest Dealer Please record the name and phone of your EcoQuest Dealer Name _________________________________________________________ Phone_________________________________________________________ Please record the serial number of your Fresh Air DuctwoRx Serial _______________________...

Page 3: ...to oxygen and hydrogen after the oxidation of a pollutant Used in conjuction with other EcoQuest air purification systems Fresh Air DuctwoRx can boost effectiveness and help distribute their benefits throughout your home Installation Requirements 1 Unit should be installed after the air handler in the HVAC system 2 The duct work around the installation area should be clean and dry to insure proper...

Page 4: ...for 3 5 opening using either the mounting plate or included template a a Using template mark 4 holes on duct b b Drill 4 holes where marked c c Cut between holes using tin snips ALTERNATIVE CUTTING METHOD 4 4 Cut hole in duct using 3 5 hole saw 2 2 Cut away insulation to expose metal duct if needed ...

Page 5: ... ...

Page 6: ... into opening Be sure the air will pass though the RCI cell honeycomb matrix 9 9 Secure the unit to the mounting plate with 4 8 32 nuts 10 10 Plug unit into working power receptacle Hard wiring unit into HVAC system should be done by a licensed HVAC installer or electrical contractor only 7 7 Secure the mounting plate using 8 8 self tapping screws METAL DUCTWORK INSTALLATION CONTINUED ...

Page 7: ...Be sure toggle anchors open after inserting 8 8 Center large opening in mounting plate over 3 5 opening in duct and press plate to duct The adhesive gasket will hold the mounting plate into place Tighten toggle bolts DO NOT OVERTIGHTEN 9 9 Insert unit into opening Be sure the air will pass though the RCI cell honeycomb matrix 10 10 Secure the unit to the mounting plate with 4 8 32 nuts FIBERGLASS ...

Page 8: ...pply 9 9 Secure unit with 4 nuts 2 2 Remove the 4 mounting nuts 8 Insert the unit into the mounting plate 6 6 Plug the new RCI cell into the base unit 5 5 Separate the used RCI cell from the base unit and dispose of properly CHANGING THE RCI CELL EcoQuest International RCI Disposal 55 Marley Drive Greeneville TN 37743 MAINTENANCE UV LAMP INDICATOR Did you forget to register your Fresh Air DuctwoRx...

Reviews: