Absolutely avoid leaning on the very edge for support as it may tilt over.
If pressure on a reduced area exceeds the allowed weight, the table upholstery could split up. Keep the
patients from getting on by their knees.

To get on the table the patient must seat at the middle of the table, raise his legs and lean on his side.
Then, he can lie down. Weight must necessarily be distributed evenly and not concentrated on either side
of the table.
When getting down the table different procedures apply depending on the position of the patient.
Therefore, if he is lying down (prone position) he has to slide gently towards the middle of the table, lean
on his side and go up by standing on his arms. He will then be able to put his legs out by the table’s side
and easily stand up.
If the patient is lying upwards he will have to stand on his arms, get back to a seated position and then go
down the table.
* Caution: Never use the head or back rest sections to lean forward as these parts are not aimed at
supporting such a pressure.

c) Height adjustment

The central height of the table is operated by an electric motor.
The motor supplied in our electric tables is sent disconnected. Before plugging the table in, connect the air
pipes according to the attached instructions.
To operate the supply cable must be plugged into a 220-230 V socket.

The height adjustment is done by smoothly pushing sideways (right/ left) the foot rails located around the
base of the table.
* Caution: DO NOT press down the foot rails; this is not a footswitch. 

* Caution: Safely position patient before table height adjustment. Do not insert hands, feet or
garments into the moving parts of the elevating mechanism as this could result in serious injuries. 

d) Sections adjustment

The head-/backrest section is operated by a gas spring (3)

The central section is operated by a gas spring (3)

The feet section is operated by rack (2)

(2) Rack: Lift the section up to the required position and the rack will position itself automatically. To lower
the section, first raise it up to a certain extend or completely (as appropriate) in order to release the rack.
* The hinges on both sides must be properly fixed and positioned at the same height.

(3) Gas spring: Press the mechanism situated at the very edge of the section towards the upholstery and
the table section will go up slowly. Release mechanism to lock position. To lower the section, press the
mechanism with one hand and with the other hand, push the section downwards to the required position.

* Caution: Never adjust any of the table sections while the patient is leaning on.
Safely position your fingers and hands away from the upholstery edge in order to avoid any
accidental jamming.

How to adjust the articulated leg supports
To adjust the height of the leg support, loose the black push-button lever to unlock the bar and move it up
or downwards to attain the required height or simply pull the bar out completely. Screw back on the lever to
lock.
To adjust the tilting of the leg support, loose the black lever under the support upholstery to unlock the
swivel plate. Next incline the leg support to the required position and screw back on the lever to lock.
By pressing the red push button of the lever you will be able to move the lever freely, no need to screw or
loose. This push button turns out to be very useful when the turning angle of the plastic levers is limited
due the short distance to the table frame.

3) MAINTENANCE

* Warning: For safety reasons, disconnect the table from the electrical supply before the table

Summary of Contents for C5581

Page 1: ...ILLA ELÉCTRICA ELECTRIC TABLE TABLE ÉLECTRIQUE INSTRUCCIONES INSTRUCTIONS Leer antes de utilizar por primera vez Read carefully before the first use A lire avant la première utilisation Actualización 24 01 2017 ...

Page 2: ...epuesto del fabricante para cada modelo en concreto Todo accesorio parte o pieza debe encajarse y colocarse de acuerdo con las instrucciones del fabricante Los componentes ajenos podrían resultar peligrosos para las personas que manejen la camilla Aviso En caso de utilizar piezas no originales o alterar el artículo la garantía del fabricante quedará anulada En este supuesto tanto las instrucciones...

Page 3: ...n Al subir y bajar la camilla asegúrese de que ni el paciente ni el terapeuta queden atrapados entre las partes móviles del mecanismo de elevación por las manos los pies o cualquier otra parte del cuerpo o prenda de ropa d Regulación de los módulos La inclinación del cabezal respaldo se regula mediante hidráulico 3 La inclinación del módulo central se regula mediante hidráulico 3 La inclinación de...

Page 4: ...epto pues comportará la anulación de la garantía En caso de mal funcionamiento contacten con Ecopostural o con su distribuidor d Tapicería Se recomienda quitar el polvo con un trapo húmedo Cuando no sea suficiente limpie con agua jabonosa y una esponja suave y seque completamente con un trapo Evite lavar y enjuagar con cantidades excesivas de agua para que no penetre por las costuras Para una mejo...

Page 5: ...rse de manera diferente con respecto a los residuos urbanos Una vez transcurrida su vida útil deberá depositarse en un centro de recogida específica La separación de desechos de productos usados y embalajes permite que los materiales puedan reciclarse y reutilizarse La reutilización de materiales reciclados ayuda a evitar la contaminación medioambiental y reduce la demanda de materias primas ...

Page 6: ...Español 6 ...

Page 7: ...tipo T13 Respaldo rectangular Orificio lágrima con tapón incluido Perneras articuladas A4705 regulables en altura y extraíbles Bandeja extraíble en acero inoxidable de 15x30x4 cm Módulo del cabezal respaldo regulable mediante pistón hidráulico Módulo central regulable mediante pistón hidráulico Módulo de la parte pies regulable manualmente mediante cremallera Peso aproximado 80 Kg Características ...

Page 8: ...l components parts or accessories should be fitted or fixed in according to the special manufacturer s instructions Any spare replacement component part different to the manufacturer s could be dangerous for the people involved in the table handling Notice The use of non original pieces or the alteration of the item will incur in a loss of validity of the manufacturer s guarantee instructions and ...

Page 9: ...vating mechanism as this could result in serious injuries d Sections adjustment The head backrest section is operated by a gas spring 3 The central section is operated by a gas spring 3 The feet section is operated by rack 2 2 Rack Lift the section up to the required position and the rack will position itself automatically To lower the section first raise it up to a certain extend or completely as...

Page 10: ...free from any dust or grease The handling of the gas spring and or the electric motor is totally forbidden Any manipulation will invalidate the guarantee If any malfunction or failure is suspected contact immediately Ecopostural or the reseller d Upholstery A wet cloth should be enough to do the dusting Anyway if the leather is not properly clean you can use a smooth sponge soaked with neutral soa...

Page 11: ...ct to a specific EC Directive and it must be followed accordingly as shown by the crossed skip symbol Therefore at the end of its useful life you will have to apply to a specialized waste disposal centre Separate Collection of used products and packaging allows materials to be recycled and used again Re use of recycled materials helps prevent environmental pollution and reduces the demand for raw ...

Page 12: ...English 12 ...

Page 13: ...ed as standard Standard backrest type T13 Square backrest Oval breather hole and bung included Articulated leg supports A4705 height adjustable and removable Stainless steel removable tray 15x30x4 cm Head Backrest adjustable by gas spring Central section adjustable by gas spring Feet section adjustable manually by rack Approx weight 80 Kg Upholstery Features Fire resistant Class M2 artificial leat...

Page 14: ...euses ou usées doivent être remplacées immédiatement par des pièces de rechange provenant du fabricant d origine pour chaque modèle de table Tout accessoire pièce ou partie entière doit s emboiter et se placer selon les instructions du fabricant Les pièces détachées d une autre marque pourraient être dangereuses pour les personnes manoeuvrant la table Avis important en cas d utilisation de pièces ...

Page 15: ...légèrement à droite ou à gauche avec le pied Attention NE JAMAIS appuyer sur la barre ce n est pas une pédale Attention Avant de faire monter ou descendre la table assurez vous que ni le patient ni le thérapeute soient en contact main pied ou tout autre partie du corps ou des vêtements avec les parties mobiles du mécanisme d élévation d Réglage des plateaux La têtière dossier se règle par vérin à ...

Page 16: ...r faire monter ou descendre la table entraîne la mise en marche de la protection thermique pour éviter une surchauffe du moteur En cas de panne contactez immédiatement Ecopostural ou votre distributeur Pour plus de détails se référer au paragraphe Questions les plus fréquentes sur les moteurs c Mécanismes pour le réglage des plateaux Assurez vous qu il n y a ni poussière ni corps gras sur les méca...

Page 17: ...ral de même que les frais d envoi des pièces jusqu au client à l intérieur de la C E Pour toute autre question concernant la garantie merci de contacter votre vendeur FABRIQUE PAR ECOPOSTURAL S L U ESB12433991 Avda Enrique Gimeno 27 ES12006 Castellón de la Plana ESPAGNE www ecopostural com info ecopostural com 34 964 25 58 06 Un appareil électronique usagé doit être traité de façon différente aux ...

Page 18: ...Français 18 ...

Page 19: ...er rectangulaire Cavité visage en forme de goutte et bouchon inclus Jambières articulées A4705 réglables en hauteur et amovibles Cuvette de 15x30x4 cm en acier inoxydable et amovible Têtière dossier réglable par vérin à gaz Partie centrale réglable par vérin à gaz Plateau jambes réglable manuellement avec crémaillère Poids approx 80 Kg Caractéristiques Sellerie Revêtement en simili cuir ignifuge d...

Reviews: