background image

Dear customers:

In order to use this machine safely, please read this user's manual carefully 
before using and installation, especially pay attention to each notice remark 
for usage and maintenance. Also keep it carefully for later use. Heat pump 
water heater is a professional machine, it may cause damage or hazard when
wrong installed. Relevant installation and maintenance shall be done by 
technical people. Please contact our installation service for reference.

          

1).When using for the first time, check if all the wiring are correct before you 
    connect the unit to power supply.
2).The specifications of fuse is: AC250V, 5A.
3).The appliance must be fitted with means for disconnection from the supply mains
     having a contact separation in all poles that provide full disconnection under
     overvoltage category III conditions, and these means must be  incorporated in the 
     fixed wiring in accordance with the wiring rules.
4). The running range of the heat pump:
     the ambient temperature range -7 ~ 43

;

     outlet water range:12 ~60

     the pressure of water 0.1MPa~0.7MPa.
5).If the power cord is damaged, please replace a new one offered from factory by 
    professional technicians.
6).Power plug's rated current shall be in accordance with the model you buy.
7).The units must be ground wired. Never connect the ground line on neutral line or 
    water pipe.
8).Product shall be singly assigned to a electrical leakage protection  power .
9).Hot water above 50

 may be burned, we suggest that you mix cold water with 

    hot water from water tank for use.
10).Any equipment must not be inserted inside the heat pump unit, in case any
     accident or abnormal operation.
11).For your safety, please DO NOT change or mend the heat pump water heater 
     yourself.
12).Closed water heaters shall be marked with a statement that a pressure-relief 
     device is to be fitted in the installation, unless it is in corporatthe appliance.
13).This appliance is not intended for use by persons (including children) with 
       reduced physical,  sensory or mental capabilities, or lack of experience and 
       knowledge, unless they have been given supervision or instruction concerning 
       use of the appliance by a person responsible for their safety.

          Important warning:

1.PREFACE

1

Summary of Contents for ZR9W Series

Page 1: ...DOMESTIC HOT WATER UNIT STATUS Heating Outlet water temp 31 Target temp 57 24 06 2011 09 28...

Page 2: ...tion 3 4 5 2 Appearance and Features 3 Working principle 3 6 5 Dimensions 7 7 7 3 Controller Introduction 7 Appendix 16 17 6 Maintenance 16 4 Installation Instruction 5 Trial Running 14 15 1 Functions...

Page 3: ...ater range 12 60 the pressure of water 0 1MPa 0 7MPa 5 If the power cord is damaged please replace a new one offered from factory by professional technicians 6 Power plug s rated current shall be in a...

Page 4: ...al transport For the manual transport the wooden pallet can be used for bottom part Using ropes or carrying straps a second or third handling configuration is possible With this type of handling care...

Page 5: ...tlet water temperature Max outlet water temperature Air volume Air pressure Duct diameter Noise Water inlet size outlet size Net dimensions Package dimensions Net weight Gross weight Compressor type 2...

Page 6: ...e g a solar heating system or a boiler Dehumidification in the recirculating air mode Dehumidified air in the laundry room supports laundry drying and prevents moisture induced damage Cooling in the...

Page 7: ...ce side heat exchanger pipes with Finned 3 lines e Air source side heat exchanger copper aluminium 2 Brief description of the heat pump ON OFF for example Users can use the controller to adjust the pa...

Page 8: ...er inlet Circulation water outlet Draining outlet 6 2 SPECIFICATION M N 35mm TYPE SIZE B A C D F E G T M V N P H 1650 1185 1025 450 250 32 5 450 925 1025 1135 925 40 560 ZR9W 200V 1535 1070 910 640 45...

Page 9: ...rget temp 55 24 06 2011 09 28 STATUS Heating Outlet water temp 31 Target temp 55 24 06 2011 09 28 Power Menu Escape Operation Instruction All parameter settings can only be adjusted setted under stand...

Page 10: ...ect Unit status Aux heating Off Fan mode On Press button to access the Main Menu see Fig 4 Press to enter FIG 5 interface for changing the setting of Aux Heating and Fan Mode function You may change s...

Page 11: ...8 Press or to change the parameter value then press ESC to confirm Press ESC again to return to last interface Out water temp adjustable range 10 60 T1 heating adjustable range 2 15 Fig 6 Fig 7 Fig 8...

Page 12: ...lue then press ESC to confirm changes press ESC to return to last interface Press or to move the cursor to ave then press to confirm and enter interface of FIG 11 Press or to choose parameter value th...

Page 13: ...n press ESC to confirm changes press ESC to return to last interface 2 4 2 TIMER ON OFF SETTING You may set both Timer 1 and Timer 2 2 period time at the same time 2 4 2 1 TIMER 1 ON OFF SETTING Move...

Page 14: ...the water loop 4 use new expansion valve The electronic heating temp protect 1 discharge the redundant gas 2 clean the air side heat exchanger The temp sensor is open or short circuit Check and replac...

Page 15: ...ff Tank top temperature Tank bottom temperature Pipe temperature Evaporator temperature Ambient temperature Swell valve 10 60 C 2 15 C 30 90 C 0 90 5min 30 90 minute 30 0 C 2 30 C 1 12 Minute 0 NO 1 Y...

Page 16: ...all power should be disconnected when servicing 8 The magnesium stick should be replaced 1 or 1 5 year according to the water quality 9 Please provide serial No on the nameplate when asking for after...

Page 17: ...water and open the water outlet tap till water flows out 3 Make sure the water pressure is normal 0 1Mpa 0 7 Mpa 4 Check the power supply is normal or not voltage range 220v 10 5 Check if all the equ...

Page 18: ...on reliability 4 Check whether pumps and water valves are normal working or not whether water tubing and water pipes connector are leakage or not 5 The unit and around should remain clean well ventila...

Page 19: ...WER 1PH 220V 50Hz HIGH PRESSURE PROTECT LOW PRESSURE PROTECT FM FAN MOTOR 4 WAY VALVE FU E HEATER 3 CONTACTOR Temp sw Temp sw FU 80 Thermostat 95 Fuse protector WIRING DIAGRAM 1 COMPRESSOR LOW PRESSUR...

Page 20: ......