Ecoplus SWBM-10.5H-B/P-S Instruction Manual Download Page 18

Wire Circuit Diagram

.Wire Circuit Diagram

Water heater

Applicable model:

 SWBM-35.0H-B-S

Note:     crank heaters marked in diagram are optional parts according to 
               customer  request!
           

15

Ambient Temp

Economizer inlet Temp

Economizer outlet Temp

Compressor side air discharge  Temp. 1

Compressor side air discharge  Temp. 2

Air fin evaporater coil tube  Temp

Outlet Water Temp

Inlet Water Temp

T1

T2

T3

T4

T5

T6

T7

T8

380v/3Ph/50Hz

Y/G

S T N

R

E

D

B

L

K

W

H

T

B

L

U

WHT

BLK

RED

CM1

R

R

T

T

CONT

ACT

OR

COMPRESSOR

Y

/G

Y

/G

C

O

M

P

R

E

S

S

O

R

C

O

N

T

A

C

T

O

R

CM2

S

S

R

S
T

R

 

Transformer

A

B

C

N1

N2

N3

3

High Press Switch

SYS1 

High Press Switch

SYS2 

SYS1 Low Press Switch

SYS2 Low Press Switch

Electric heater protect

Water flow

Wire
Controller

CZ1   C

Z2   C

Z3  C

Z4   C

Z5   C

Z6   C

Z7  C

Z8   C

Z9  C

Z10

5

5

Electronic 
 Expansion 
Valve 1

 

Electronic 

 Expansion 
 Valve 2

SW1     S

W2

T8 T7 T6 T5 T4 T3 T2 T1

ON

1 2 1 2

ON

 E

c

o

n

o

m

iz

e

r

m

a

g

h

ti

sm v

a

lv

e

F M 3

F M 1

F M 4

F M 2

 

Fan Motor

 

Fan Motor

S

4

-W

A

Y

1

4

-W

A

Y

2

T

 S

w

ic

h

a

b

le 

m

a

g

h

ti

sm v

a

lv

e

 S

w

ic

h

a

b

le 

m

a

g

h

ti

sm v

a

lv

e

 S

w

ic

h

a

b

le 

m

a

g

h

ti

sm v

a

lv

e

 S

w

ic

h

a

b

le 

m

a

g

h

ti

sm v

a

lv

e

C

O

N

T

A

C

T

O

R 2

C

O

N

T

A

C

T

O

R 1

R

Electric heater

Water Pump

C

R

A

N

K

S

H

A

F

T

 H

E

A

T

E

R

C

H

A

S

S

IS H

E

A

T

E

R

1    2     3    4    5     6    7     8     9  10  11   12  13  14

 SWBM-35.0H-B-S

LOW AMBIENT HEAT PUMP WIRING DIAGRAM

Second 

set point 

switch

Long distance 

demand

15 16 17 18

Summary of Contents for SWBM-10.5H-B/P-S

Page 1: ...Installation Instruction Manual LOW AMBIENT HEAT PUMP WATER HEATER MODEL SWBM 10 5H B P S SWBM 17 5H B P S SWBM 35 0H B S...

Page 2: ......

Page 3: ...customers Product Introducing 2 Work principle 3 Performance Data 4 Dimension 5 Operation introductions 8 Wire Circuit Diagram 14 Installation instructions 16 Maintenance 20 1 CONTENTS Water heater C...

Page 4: ...omponents without switching off the electrical supply to the unit Electric leakage switch protection device MUST be installed 3 It is forbidden to start any work on the electrical components if water...

Page 5: ...Heat pump not only use less electricity to get heat from ambient air but are also able to combine using with solar equipment will not cause pollution and no poison gas exhausting All Round The Year Ho...

Page 6: ...mpressor compress it the refrigerant gas became high temperature and high pressure Then the gas come into the water condensation into liquid emit a lot of condensation heat condensing heat absorbed by...

Page 7: ...et Weight Gross Weight Unit Dimension L W H Weight kg Kpa Water pump Power Head M KW RPM dB A inch 3 m h mm mm W V PH Hz COP W W Running Current Heating A Heating Input Power W Scroll SWBM 17 5H B P S...

Page 8: ...Water heater Dimension Measure mm The dimension for air source heat pump water heater SWBM 10 5H B P S 5 804 1510 1362 565 460 420 500...

Page 9: ...Measure mm The dimension for air source heat pump water heater SWBM 17 5H B P S low ambient Dimension Water heater 6 1300 765 420 1370 460 500...

Page 10: ...The dimension for low ambient air source heat pump water heater SWBM 35 0H B S Dimension Water heater Measure mm 7 1850 1580 508 1790 880 460 500...

Page 11: ...ss to turn on or turn off the heat pump 2 1 2 After entering parameter or clock setting press once to return to main interface Start up state Stand by state 1 2 Initialization Operation introductions...

Page 12: ...d keyboard is locked 3 2 2 Under locked state press both and at the same time for 5 seconds after Dee sound keyboard is unlocked heat pu Clock setting 3 3 Clock Setting 3 3 1 On main interface press o...

Page 13: ...n minute 3 4 4 After setting the minutes press once to confirm and save all the Timer On setting and switch to Timer Off setting interface At this moment the hour of clock shows and flashes press or t...

Page 14: ...31 32 Display also even system is not start up Actual testing value Actual testing value Actual testing value Actual testing value Actual testing value Actual testing value Actual testing value Actual...

Page 15: ...or failure Ambient 12 System parameter setting 3 5 2 On the interface of Parameter and Status inquiry if not pressing any button within 10 seconds system automatically exit the inquiry interface and r...

Page 16: ...em 1 compressor high pressure failure System 1 compressor low pressure failure System 1 compressor air exhausting temperature too high power phase failure Auxiliary heater temperature too high protect...

Page 17: ...lve Fan Motor Swichable maghtism valve Wire Controller Transformer U CONTACTOR 1 V W YLW GRN Ambient Temp Economizer inlet Temp Economizer outlet Temp Compressor side air discharge Temp Air fin evapor...

Page 18: ...er A B C N1 N2 N3 3 High Press Switch SYS1 High Press Switch SYS2 SYS1 Low Press Switch SYS2 Low Press Switch Electric heater protect Water flow Wire Controller C Z 1 C Z 2 C Z 3 C Z 4 C Z 5 C Z 6 C Z...

Page 19: ...o the distance between the barriers shown in below picture pay attention to arrow direction Water tank 1Water tanks should be placed where ambient temperature is above 0 1Can be installed outdoors or...

Page 20: ...own on the manual and in accordance with national corresponding construction standards 1Installation of water pipes should be straight and flat pipeline collocation should be rational ensure to minimi...

Page 21: ...ck the electricity distribution System 1Check if the power supply same as shown on manual and rating label 1Check if all the power supply and control wiring are all well connected check if the wiring...

Page 22: ...2 minutes 1 When water pump is on and the high level switch cut off if water temperature set Temperature 5 degrees shut down water supply for tanks If water tank temperature temperature 2 degrees the...

Page 23: ...around should remain clean well ventilated Regularly clean 1 2 month the side air heat exchanger to maintain a good effect of heat exchange 7 Frequently check whether each part of the unit work normal...

Page 24: ...Air Source Heat Pump Water Heater...

Reviews: