Ecoplus SWBM-10.5H-B/P-S Instruction Manual Download Page 14

Operation introductions

.Operation introductions

Water heater

Operation introductions

.Operation introductions

Water heater

3.5

  

System Parameter & Status Inquiry

      

On main interface, press 

      

 to enter the inquiry interface of temperature sensor

      

and electric expansion status, press

      

and

     

can check each parameter

 

status.

3.5.1  Press 

     

for 5 seconds to check parameter setting value, press 

     

 

     

           to check each system's parameter  setting value.

or

Parameter                       Content                                    Range               Default value        Remark

Water in temperature sensor

Water out temperature sensor

Ambient temperature sensor

System 1- coil tube temperature 
sensor

System 1- air exhausting 
temperature sensor

System 2- air exhausting 
temperature sensor

Electrical expansion valve
 current steps

 Reserved

Model parameter

-20

99

-20

99

-20

99

-20

99

-20

99

-20

90

0

125

0

125

150

450

0

20

60

1

℃~

20

15

90min

1

℃~

20

-30

℃~

0

1

℃~

30

30

90min

1

12min

15

45

100

125

0

1

50

℃~

60

20

℃~

40

40

5

30min

5

-3

14

45min

8min

25

110

1

60

35

0

0

0

1

0

2

0

3

0

4

0

5

0

6

0

7

0

8

0

9

1

0

20

21

22

23

24

25

26

27

28

29

30

31

32

Display also even 
system is not start up

Actual testing
 value
Actual testing
 value
Actual testing
 value
Actual testing
 value
Actual testing
 value
Actual testing
 value
Actual testing
 value
Actual testing
 value
Actual testing
 value

Actual testing
 value

             

0/1/2/3

0 :for single phase power
    single system, 
1: for single phase power 
    dual system , 
2: for 3 phase power single 
    system, 
3: for 3 phase power dual
     system

Control

Parameter

       Meaning of Setting parameter          Range       Default              Remark

Return water setting temperature

Heating temperature difference (heat pump)

Auxiliary heater starting delay time

Auxiliary heater return temperature difference

Temperature to enter defrosting

Temperature to exit defrosting

defrosting period

Max defrosting time

electric expansion valve initiate value

Air exhausting protection temperature value

Memory record for power disconnection

Second set point (mamimum setting temp range)

Second set point (minimum setting temp range)

Actual impulsion = 

setting value*10

1 means record the memory

if any  power disconnection

11

System 1-  

 outlet

temperature sensor

Economizer

System 1- 
temperature sensor

Economizer

 

inlet

Only validity when S1 switch

connected

Only validity when S1 switch

connected

Summary of Contents for SWBM-10.5H-B/P-S

Page 1: ...Installation Instruction Manual LOW AMBIENT HEAT PUMP WATER HEATER MODEL SWBM 10 5H B P S SWBM 17 5H B P S SWBM 35 0H B S...

Page 2: ......

Page 3: ...customers Product Introducing 2 Work principle 3 Performance Data 4 Dimension 5 Operation introductions 8 Wire Circuit Diagram 14 Installation instructions 16 Maintenance 20 1 CONTENTS Water heater C...

Page 4: ...omponents without switching off the electrical supply to the unit Electric leakage switch protection device MUST be installed 3 It is forbidden to start any work on the electrical components if water...

Page 5: ...Heat pump not only use less electricity to get heat from ambient air but are also able to combine using with solar equipment will not cause pollution and no poison gas exhausting All Round The Year Ho...

Page 6: ...mpressor compress it the refrigerant gas became high temperature and high pressure Then the gas come into the water condensation into liquid emit a lot of condensation heat condensing heat absorbed by...

Page 7: ...et Weight Gross Weight Unit Dimension L W H Weight kg Kpa Water pump Power Head M KW RPM dB A inch 3 m h mm mm W V PH Hz COP W W Running Current Heating A Heating Input Power W Scroll SWBM 17 5H B P S...

Page 8: ...Water heater Dimension Measure mm The dimension for air source heat pump water heater SWBM 10 5H B P S 5 804 1510 1362 565 460 420 500...

Page 9: ...Measure mm The dimension for air source heat pump water heater SWBM 17 5H B P S low ambient Dimension Water heater 6 1300 765 420 1370 460 500...

Page 10: ...The dimension for low ambient air source heat pump water heater SWBM 35 0H B S Dimension Water heater Measure mm 7 1850 1580 508 1790 880 460 500...

Page 11: ...ss to turn on or turn off the heat pump 2 1 2 After entering parameter or clock setting press once to return to main interface Start up state Stand by state 1 2 Initialization Operation introductions...

Page 12: ...d keyboard is locked 3 2 2 Under locked state press both and at the same time for 5 seconds after Dee sound keyboard is unlocked heat pu Clock setting 3 3 Clock Setting 3 3 1 On main interface press o...

Page 13: ...n minute 3 4 4 After setting the minutes press once to confirm and save all the Timer On setting and switch to Timer Off setting interface At this moment the hour of clock shows and flashes press or t...

Page 14: ...31 32 Display also even system is not start up Actual testing value Actual testing value Actual testing value Actual testing value Actual testing value Actual testing value Actual testing value Actual...

Page 15: ...or failure Ambient 12 System parameter setting 3 5 2 On the interface of Parameter and Status inquiry if not pressing any button within 10 seconds system automatically exit the inquiry interface and r...

Page 16: ...em 1 compressor high pressure failure System 1 compressor low pressure failure System 1 compressor air exhausting temperature too high power phase failure Auxiliary heater temperature too high protect...

Page 17: ...lve Fan Motor Swichable maghtism valve Wire Controller Transformer U CONTACTOR 1 V W YLW GRN Ambient Temp Economizer inlet Temp Economizer outlet Temp Compressor side air discharge Temp Air fin evapor...

Page 18: ...er A B C N1 N2 N3 3 High Press Switch SYS1 High Press Switch SYS2 SYS1 Low Press Switch SYS2 Low Press Switch Electric heater protect Water flow Wire Controller C Z 1 C Z 2 C Z 3 C Z 4 C Z 5 C Z 6 C Z...

Page 19: ...o the distance between the barriers shown in below picture pay attention to arrow direction Water tank 1Water tanks should be placed where ambient temperature is above 0 1Can be installed outdoors or...

Page 20: ...own on the manual and in accordance with national corresponding construction standards 1Installation of water pipes should be straight and flat pipeline collocation should be rational ensure to minimi...

Page 21: ...ck the electricity distribution System 1Check if the power supply same as shown on manual and rating label 1Check if all the power supply and control wiring are all well connected check if the wiring...

Page 22: ...2 minutes 1 When water pump is on and the high level switch cut off if water temperature set Temperature 5 degrees shut down water supply for tanks If water tank temperature temperature 2 degrees the...

Page 23: ...around should remain clean well ventilated Regularly clean 1 2 month the side air heat exchanger to maintain a good effect of heat exchange 7 Frequently check whether each part of the unit work normal...

Page 24: ...Air Source Heat Pump Water Heater...

Reviews: